A resolution criterion for electron tomography based on cross-validation.

نویسندگان

  • Giovanni Cardone
  • Kay Grünewald
  • Alasdair C Steven
چکیده

Despite much progress in electron tomography, quantitative assessment of resolution has remained a problematic issue. The criteria that are used in single particle analysis, based on gauging the consistency between density maps calculated from half data sets, are not directly applicable because of the uniqueness of a tomographic volume. Here, we propose two criteria based on a cross-validation approach. One, called FSC(e/o), is based on a Fourier shell correlation comparison between tomograms calculated from the even and odd members of a tilt series. The other, called noise-compensated leave-one-out (NLOO), is based on Fourier ring correlation comparisons between an original projection and the corresponding reprojection of the tomogram calculated from all the other projections, taking into account the differing noise statistics. Plotted as a function of tilt angle, they allow assessment of the angular dependence of resolution and quality control over the series of projections. Integrated over all projections, the results give a global figure for resolution. Tests on simulated tomograms established consistency between these criteria and the FSC(ref), a correlation coefficient calculated between a known reference structure and the corresponding portion of a tomogram containing that structure. The two criteria-FSC(e/o) and NLOO-are mutually consistent when residual noise is the major resolution-limiting factor. When the size of the tilt increment becomes a significant factor, NLOO provides a more reliable criterion, as expected, although it is computationally intensive. Applicable to entire tomograms or selected structures, NLOO has also been tested on experimental tomographic data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation and evaluation of a GATE model for MAMMI PET scanner

Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard.  Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...

متن کامل

Cross-linguistic Validation of Processability Theory: The Case of EFL Iranian Students’ Speaking Skill

Abstract This study investigated the validity of processability theory proposed by Pienemann (1998/2015) among Iranian EFL learners’ oral performance. The theory defines six procedural stages for learners in the process of second language acquisition. In order to conduct the study, 10 intermediate EFL learners were selected based on their performance on Oxford Placement Test. Then, they partici...

متن کامل

Cross-linguistic Validation of Processability Theory: The Case of EFL Iranian Students’ Speaking Skill

Abstract This study investigated the validity of processability theory proposed by Pienemann (1998/2015) among Iranian EFL learners’ oral performance. The theory defines six procedural stages for learners in the process of second language acquisition. In order to conduct the study, 10 intermediate EFL learners were selected based on their performance on Oxford Placement Test. Then, they partici...

متن کامل

Presenting a Model for Predicting Tax Evasion of Guilds Based on Data Mining Technique

In this research, considering the importance of the topic and the gap in previous researches, a model for predicting tax evasion of guilds based on data mining technique is presented. The analyzed data includes the review of 5600 tax files of all trades with tax codes in Qazvin province during the years 2013-2018. The tax file related to guilds is in five tax groups, including the guild group o...

متن کامل

Truncated Total Least Squares Method with a Practical Truncation Parameter Choice Scheme for Bioluminescence Tomography Inverse Problem

In bioluminescence tomography (BLT), reconstruction of internal bioluminescent source distribution from the surface optical signals is an ill-posed inverse problem. In real BLT experiment, apart from the measurement noise, the system errors caused by geometry mismatch, numerical discretization, and optical modeling approximations are also inevitable, which may lead to large errors in the recons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of structural biology

دوره 151 2  شماره 

صفحات  -

تاریخ انتشار 2005