Effects of optical diameter of intraocular lenses with intrascleral fixation on higher-order aberrations

نویسندگان

  • Daisuke Kunita
  • Makoto Inoue
  • Yuji Itoh
  • Naoko Matsuki
  • Toshiyuki Nagamoto
  • Akito Hirakata
چکیده

BACKGROUND Intrascleral fixation of an intraocular lens (IOL) is used in eyes that lack capsular support. The aim of the study is to determine whether a larger optical diameter IOL will decrease the higher-order aberrations (HOAs) when the haptics are extended for intrascleral fixation than a smaller diameter IOL. METHODS Three-piece acrylic IOLs with 6.0 mm optics (X-60, VA-60BBR) and 7.0 mm optics (X-70, VA-70 AD) were fixed at lengths of 13, 14, 15, 16, or 17 mm. A wavefront analyzer was used to measure the HOAs within the central 3.0 and 5.2 mm optic diameter. RESULTS The astigmatic aberration within the central 5.2 mm was greater than that within the central 3.0 mm for all IOLs. The HOAs increased significantly with an extension of the IOLs with both optical diameters (P < 0.001). The coma aberration within the central 5.2 mm was greater than that within the central 3.0 mm but it did not increase with an extension of the haptics. The astigmatic aberration of the X-60 IOL was significantly greater than that of the X-70 only at an extension of 17 mm. The astigmatic aberration of the VA-70 AD was not significantly different from that of the VA-60BBR. The cylindrical power changed from 0.047 D in the X-60 to 0.118 D in the VA-70 AD when the IOLs were extended from 13 to 17 mm. CONCLUSION When three-piece IOLs are highly extended for intrascleral fixation, the astigmatic aberration increases significantly. However, IOLs with 7 mm optics do not have less astigmatic and coma aberrations than IOLs with 6 mm optics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار

Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...

متن کامل

Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses.

PURPOSE To characterize and measure the ocular aberrations in eyes implanted with monofocal intraocular lenses (IOLs) and to study any correlation between postoperative aberrations and surgical factors. METHODS A Tscherning aberroscope was used to measure the wavefront aberrations of 62 eyes that had undergone phacoemulsification with the implantation of foldable monofocal Acrysof MA60BM IOLs...

متن کامل

Surgical Outcome of Simultaneous Intraocular Lens Rescue and Sutureless Intrascleral Tunnel Fixation of Dislocated Intraocular Lenses.

PURPOSE To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). METHODS Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 2...

متن کامل

Tips and Tricks of Intrascleral Fixation of Single-Piece and Toric Intraocular Lens

Various techniques for scleral fixation of IOL in cases of poor capsular support have been described in past. Sutured scleral fixation of IOLs has been attempted for single piece and toric IOLs also. But this predisposes to various suture releated complications. Sutureless fixation of three piece IOLs with or without glue has gained popularity worldwide. However, odd power lenses and high astig...

متن کامل

Optical performance of monofocal versus multifocal intraocular lenses.

In their recent paper, Ortiz et al. studied the optical performance of monofocal and multifocal intraocular lenses (IOLs) in the human eye. Their main conclusion was that of the IOLs studied, the hybrid refractive–diffractive IOLwas the least affected by pupil diameter in terms of intraocular aberrations. This IOL type also showed a smaller increase in optical aberrations during pupil dilation....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017