A fractured and immovable ceramic liner in a screw-fixed acetabular shell during total hip arthroplasty: a case report.

نویسندگان

  • Usman Butt
  • David Knowles
چکیده

We report a complication during total hip arthroplasty using an uncemented press-fit acetabular shell and ceramic liner for a woman with osteoarthritis. Fracture of the ceramic liner occurred during its insertion owing to non-concentric reduction. The main body of the ceramic liner became wedged in the acetabular shell and was resistant to removal. The shell itself was immovable owing to the prior insertion of 2 polyaxial screws, to which access was covered. Successful removal involved drilling a hole in the ceramic liner as a stress riser, and then cracking the liner with a Steinman pin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraction of a well fixed but fractured ceramic acetabular liner

Ceramic fractures have been reported to occur in hip replacements, but the techniques used to extract a well fixed but fractured component are not commonly described. We present a case of ceramic liner fracture and validate a modification of a previously reported extraction technique that allowed us to save the acetabular cup and insert a polyethylene liner. With an increasing trend in ceramic ...

متن کامل

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

Intrapelvic protrusion of the ceramic head resulting from forte ceramic liner fracture without a significant trauma: a case report.

In this article, we present a 48-year-old female case who had an unsuccessful previous forte ceramic-on-ceramic total hip arthroplasty for early coxarthrosis secondary to acetabular dysplasia. She had fracture and protrusion of the ceramic liner through the titanium acetabular shell without any apparent trauma, possibly resulting from the mistake during the implantation of the ceramic liner int...

متن کامل

Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty

INTRODUCTION Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied e...

متن کامل

Pseudotumour Complicated by Implant Loosening One Year After revision Ceramic on Metal Total Hip Arthroplasty: A Case Report

INTRODUCTION Pseudotumor is not an uncommon complication after total hip arthroplasty (THA). This can occur in relationship to different bearing surfaces of head and liner ranging from soft to hard articulation. There is wide spectrum of presentation from asymptomatic to implant failure. CASE REPORT We report a case of pseudotumor formation with acetabular cup aseptic loosening after revision...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2012