Biomechanical comparison of a novel castless arthrodesis plate with T-plate and cross pin techniques for canine partial carpal arthrodesis.
نویسندگان
چکیده
OBJECTIVES To describe a novel canine castless partial carpal arthrodesis plate (par-CA) and its ex vivo biomechanical comparison with T-plate and cross pinning techniques for canine partial carpal arthrodesis. METHODS The three implant systems were applied to three cohorts of six forelimbs from Greyhounds euthanatized for reasons unrelated to the study. Intercarpal and carpometacarpal palmar fibrocartilage and ligaments were sectioned. Potentiometers were applied between the radial carpal and third metacarpal bones to measure micromotion, and limbs were loaded at 30% of bodyweight at 1 Hertz for 10,000 cycles on a servo-hydraulic universal testing machine. Following assessment of micromotion, limbs were loaded to failure at 20 mm/s and ultimate strength, ultimate displacement, and stiffness were measured. RESULTS The T-plate (p <0.01) and par-CA (p <0.01) had reduced micromotion relative to the cross pin constructs but there was no significant difference between the control, T-plate and par-CA constructs. There was no significant difference in ultimate strength between constructs. Ultimate displacement was reduced in the plated constructs. Stiffness did not differ between constructs. CLINICAL SIGNIFICANCE The novel par-CA construct was biomechanically similar to the T-plate and both were superior to cross pins in resisting micromotion. There was no difference in load at failure between constructs. The par-CA plate permits radial and ulnar carpal bone compression, a more distal location of the plate to limit impingement, and placement of screws in two metacarpal bones; features which may offer clinical benefits over T-plate fixation.
منابع مشابه
First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملBilateral Pancarpal Arthrodesis in a German Shepherd Dog
Case Description- A 5-year old male German shepherd weighting 28 kg with the history of falling from the third floor 9 month previous was referred to the Small Animal Hospital. Clinical Findings- In clinical examination roughness and thickness of the skin of the palmar surface of both forelimbs were felt. The animal was using his palmar plane of both forelimbs to walk without any signs of pain ...
متن کاملAnterior Ankle Arthrodesis with Molded Plate: Technique and Outcomes
Background: There is still controversy regarding the best technique for ankle arthrodesis to acheive stable rigid fixation along with reconstructing a functional plantigrade foot. Moreover, existing techniques have complictions related to stability, soft tissue covering, fusion rate, and exposure. Methods: With the anterior approach exactly on the tibialis anterior sheath, the joint was expose...
متن کاملBiomechanical comparison of three fixation techniques used for four-corner arthrodesis.
Clinical results following four-corner arthrodesis vary and suggest that nonunion may be related to certain fixation techniques. The purpose of our study was to examine the displacement between the lunate and capitate following a simulated four-corner arthrodesis with the hypothesis that three types of fixation (Kirschner wires, dorsal circular plate, and a locked dorsal circular plate) would a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary and comparative orthopaedics and traumatology : V.C.O.T
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2013