Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use.
نویسندگان
چکیده
OBJECTIVE(S) We compared a convenient, cuffless, wrist-type ambulatory blood pressure monitoring (ABPM) device (BPro) and a standard arm-type ABPM monitor under ambulatory conditions. METHODS Fifty normotensive and prehypertensive volunteers who had no interarm differences in BP were enrolled. The wrist and arm monitors were attached to the left wrist and the right arm, respectively, and provided readouts at 15 and 30-min intervals, respectively. Ambulatory BP levels and the extent of agreement by intraclass correlation were evaluated. In 15 of the 50 participants, we also examined values at different arm positions: heart level, above the head, and hanging at the sides. RESULTS The awake mean systolic blood pressure (SBP) values (122±13 vs. 127±11 mmHg, P<0.01) were significantly lower with the wrist monitor than the arm monitor, and the mean sleep diastolic blood pressure (DBP) (71±8 vs. 64±8 mmHg, P<0.01) was significantly higher with the wrist monitor than the arm monitor. The intraclass correlation values between the monitors were 0.54 for 24 h SBP and 0.52 for awake SBP, considered to indicate a moderate agreement. The BP values in the arm-raised position were significantly higher for the wrist monitor than for the arm monitor (SBP: 129±14 vs. 108±14 mmHg, P<0.01; DBP: 83±13 vs. 64±11 mmHg, P<0.01). However, the SBP and DBP values in the other arm positions were similar between the monitors. CONCLUSION The wrist monitor showed fair agreement with the arm monitor in the ambulatory condition, and was stable irrespective of arm positions.
منابع مشابه
Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference.
BACKGROUND Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be use...
متن کاملReproducibility of wrist home blood pressure measurement with position sensor and automatic data storage
BACKGROUND Wrist blood pressure (BP) devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using established validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. METHODS To c...
متن کاملShort Sleep Duration Measured by Wrist Actimetry Is Associated With Deteriorated Glycemic Control in Type 1 Diabetes
OBJECTIVE Sleep restriction has been associated with deteriorated insulin sensitivity. The effects of short sleep duration have been explored little in patients with type 1 diabetes. This study addresses the question of whether sleep curtailment affects HbA1c levels in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS Seventy-nine adult patients with type 1 diabetes (median age 40 ye...
متن کاملInaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?
BACKGROUND Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. METHOD This study compared BP measured by two oscillometric de...
متن کاملThe role of stress on the rise of blood pressure
Background: The virtual rise of blood pressure resulted from stress, that is observed in subjects that are tested in medical centers, can be oftenly corrected by holter. This phenomenon causes such persons not to response to the common anti blood pressure treatments (2). Materials and methods: This descriptive study was conducted 2006-2007 at the heart clinic of Shohadaye–Ashayer hospital in Kh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood pressure monitoring
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2013