Fabrication of co-planar screen printed microband electrodes.
نویسندگان
چکیده
We demonstrate the first example of the fabrication of co-planar 50 μm (width) screen printed graphite microbands (length: 20 mm), fabricated entirely via screen printing which are characterised both microscopically and electrochemically via cyclic voltammetry and evaluated towards the sensing of NADH offering a competitive limit of detection (3σ) of 0.24 μM. The fabricated electrodes are also shown to be extended to gold screen printed microbands which are evaluated towards the sensing of chromium(VI) offering a limit of detection (3σ) of 2.65 μM. These microbands are seen to be the first produced entirely through screen printed technology potentially allowing disposable, mass produced microbands to be realised.
منابع مشابه
Screen-printed back-to-back electroanalytical sensors: heavy metal ion sensing.
Screen-printed back-to-back microband electroanalytical sensors are applied to the quantification of lead(II) ions for the first time. In this configuration the electrodes are positioned back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor. Pr...
متن کاملScreen-printed back-to-back electroanalytical sensors.
We introduce the concept of screen-printed back-to-back electroanalytical sensors where in this facile and generic approach, screen-printed electrodes are printed back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor would be. This approach uti...
متن کاملThe fabrication, characterisation and electrochemical investigation of screen-printed graphene electrodes.
We report the fabrication, characterisation (SEM, Raman spectroscopy, XPS and ATR) and electrochemical implementation of novel screen-printed graphene electrodes. Electrochemical characterisation of the fabricated graphene electrodes is undertaken using an array of electroactive redox probes and biologically relevant analytes, namely: potassium ferrocyanide(II), hexaammine-ruthenium(III) chlori...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 138 9 شماره
صفحات -
تاریخ انتشار 2013