Force-Sensor-Based Estimation of Needle Tip Deflection in Brachytherapy
نویسندگان
چکیده
A virtual sensor is developed for the online estimation of needle tip deflection during permanent interstitial brachytherapy needle insertion. Permanent interstitial brachytherapy is an effective, minimally invasive, and patient friendly cancer treatment procedure. The deflection of the needles used in the procedure, however, undermines the treatment efficiency and, therefore, needs to be minimized. Any feedback control technique to minimize the needle deflection will require feedback of this quantity, which is not easy to provide. The proposed virtual sensor for needle deflection incorporates a force/torque sensor, mounted at the base of the needle that always remains outside the patient. The measured forces/torques are used by a mathematical model, developed based on mechanical needle properties. The resulting estimation of tip deflection in real time during needle insertion is the main contribution of this paper. The proposed approach solely relies on the measured forces and torques without a need for any other invasive/noninvasive sensing devices. A few mechanical models have been introduced previously regarding the way the forces are composed along the needle during insertion; we will compare our model to those approaches in terms of accuracy. In order to conduct experiments to verify the deflection model, a custom-built, 2-DOF robotic system for needle insertion is developed and discussed.This system is a prototype of an intelligent, hand-held surgical assistant tool that incorporates the virtual sensor proposed in this paper.
منابع مشابه
Master-Thesis Development of a Surgical Assistant System for Needle Adjustment in Prostate Brachytherapy
Title of the Master-Thesis Development of a Surgical Assistant System for Needle Adjustment in Prostate Brachytherapy Author: 1. Examiner: 2. Examiner: Semester: Thomas Lehmann Prof. Dr.-Ing. Bernhard Vondenbusch, Hochschule Furtwangen University Mahdi Tavakoli, PhD, University of Alberta BME 3 Abstract: The prototype of a robotic surgical assistant system was developed for prostate brachythera...
متن کاملEffects of Tip Geometry of Surgical Needles: an Assessment of Force and Deflection
Precise placement and steering of surgical needles is very important for many medical diagnostic and therapeutic procedures. But accurate steering and placement of needles in soft tissue is challenging because of a variety of reasons. In this study we focused on the effects of tip geometry (bevel tip, diamond tip, and conical tip) of brachytherapy needles while inserted in soft material phantom...
متن کاملDesign, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force
This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...
متن کاملDesign and Modeling of a New Type of Tactile Sensor Based on the Deformation of an Elastic Membrane
This paper presents the design and modeling of a flexible tactile sensor, capable of detecting the 2D surface texture image, contact-force estimation and stiffness of the sensed object. The sensor is made of polymer materials. It consists of a cylindrical chamber for pneumatic actuation and a membrane with a mesa structure. The inner radius of the cylindrical chamber is 2cm and its outer radius...
متن کاملNeedle Deflection during Insertion into Soft Tissue Based on Virtual Spring Model
Needle insertion is the most common procedure of minimally invasive interventions. During insertion into a soft tissue, the needle with bevel tip can deflect due to the asymmetric forces acting on the tip of the needle. In this paper, a mechanics-based model is developed to predict the needle deflection. In the model, the needle is considered as a cantilever beam supported by a series of nonlin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- J. Sensors
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013