Quantifizierung von Angiotensin-II- Rezeptor Antagonisten in Humanplasma mittels LC-MS/MS
نویسندگان
چکیده
For the quantitation of angiotensin II receptor antagonist drugs (ARA-II) in human plasma, a method using liquid-chromatography (LC)-electrospray ionization tandem mass spectrometry (MS/MS) has been developed with respect to simple sample clean-up and investigation of ion suppression effects. For sample preparation, protein precipitation using zinc sulphate and methanol showed advantages in speed, recovery, and reproducibility over solid-phase extraction. A triple quadrupole mass spectrometer (Sciex API 365) with turbo ionspray source was used for detection of compounds with multireaction monitoring (MRM) of two transitions per compound. Suppression effects caused by endogenous matrix compounds were investigated by post-column infusion of analytes and LC analysis of precipitates of blank plasma samples and could be excluded. A validation was performed for the ARA-II drugs (valsartan, irbesartan, losartan and its active metabolite EXP 3174, eprosartan, candesartan, and telmisartan). The developed method showed good intraand interday precision (12% relative standard deviation) and accuracy (11.5% bias) at different concentrations for all the studied compounds. The calculated lower limits of quantitation were between 7 and 13 ng/mL, and the compounds were stable during the analytical process. These rather expensive drugs against hypertension are prescribed with increasing numbers in Europe and the industrialized nations. Complications might arise from overdosage or metabolic disorders. However, drug monitoring is not usually performed. Because the therapeutic concentrations range from a few nanograms to hundreds of nanograms per milliliter for the different drugs, and they are not amenable to gas chromatography/MS analysis because of their high molecular weight and polarity, the LC-MS/MS method is the golden standard for therapeutic drug monitoring and for clinical and forensic toxicology of ARA-II drugs.
منابع مشابه
Letter to the editor: Angiotensin quantification by mass spectrometry.
TO THE EDITOR: With great interest, we have read Mark Chappell’s (4) comprehensive overview on molecular components of the renin-angiotensin system (RAS). It focused on the analytical methods that can be used to determine the activity or concentration of these molecules, with special emphasis on RIA and ELISA. We fully agree that the sampling procedure is critical to obtain reliable data on ang...
متن کاملLabel-free quantitative analysis of one-dimensional PAGE LC/MS/MS proteome: application on angiotensin II-stimulated smooth muscle cells secretome.
A widely used method for protein identification couples prefractionation of protein samples by one-dimensional (1D) PAGE with LC/MS/MS. We developed a new label-free quantitative algorithm by combining measurements of spectral counting, ion intensity, and peak area on 1D PAGE-based proteomics. This algorithm has several improvements over other label-free quantitative algorithms: (i) Errors in p...
متن کاملLabel-free Quantitative Analysis of One-dimensional PAGE LC/MS/MS Proteome APPLICATION ON ANGIOTENSIN II-STIMULATED SMOOTH MUSCLE CELLS SECRETOME*□S
A widely used method for protein identification couples prefractionation of protein samples by one-dimensional (1D) PAGE with LC/MS/MS. We developed a new labelfree quantitative algorithm by combining measurements of spectral counting, ion intensity, and peak area on 1D PAGE-based proteomics. This algorithm has several improvements over other label-free quantitative algorithms: (i) Errors in pe...
متن کاملReply to "Letter to the editor: Angiotensin quantification by mass spectrometry".
REPLY: Although I appreciate the comments from Poglitsch and colleagues in their letter (5), their assertion that my review concluded that liquid chromatography-mass spectrometry (LCMS) lacks the sensitivity to quantify endogenous angiotensins and requires exogenous renin for peptide detection is surprising and quite incorrect. I discussed multiple LC-MS studies that quantified angiotensins in ...
متن کاملKosten- und Nutzenaspekte von IT-basierten Rückverfolgbarkeits- und Qualitätssicherungssystemen. Ergebnisse einer Delphi-Studie
Lebensmittelskandale haben in der Agrarund Ernährungsindustrie zu Rückverfolgbarkeitslösungen unterschiedlichster Ausprägung geführt. Empirische Aussagen über die Relevanz einzelner Kostenbzw. Nutzenaspekte der Stakeholder von IT-basierten Qualitätssicherungsund Rückverfolgbarkeitssystemen liegen derzeit nicht vor. Ziel des Forschungsvorhabens ist daher die Identifizierung und Quantifizierung d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008