Quality improvement process to assess tattoo alignment, set-up accuracy and isocentre reproducibility in pelvic radiotherapy patients

نویسندگان

  • Kelly Elsner
  • Kate Francis
  • George Hruby
  • Stephanie Roderick
چکیده

INTRODUCTION This quality improvement study tested three methods of tattoo alignment and isocentre definition to investigate if aligning lateral tattoos to minimise pitch, roll and yaw decreased set-up error, and if defining the isocentre using the lateral tattoos for cranio-caudal (CC) position improved isocentre reproducibility. The study population was patients receiving curative external beam radiotherapy (EBRT) for prostate cancer. The results are applicable to all supine pelvic EBRT patients. METHODS The three sequential cohorts recruited 11, 11 and 10 patients respectively. A data set of 20 orthogonal pairs of electronic portal images (EPI) was acquired for each patient. EPIs were matched offline to digitally reconstructed radiographs. In cohort 1, lateral tattoos were adjusted to minimise roll. The anterior tattoo was used to define the isocentre. In cohort 2, lateral tattoos were aligned to minimise roll and yaw. Isocentre was defined as per cohort 1. In cohort 3, lateral tattoos were aligned as per cohort 2 and the anterior tattoo was adjusted to minimise pitch. Isocentre was defined by the lateral tattoos for CC position and the anterior tattoo for the left-right position. RESULTS Cohort 3 results were superior as CC systematic and random set-up errors reduced from -1.3 mm to -0.5 mm, and 3.1 mm to 1.4 mm respectively, from cohort 1 to cohort 3. Isocentre reproducibility also improved from 86.7% to 92.1% of treatment isocentres within 5 mm of the planned isocentre. CONCLUSION The methods of tattoo alignment and isocentre definition in cohort 3 reduced set-up errors and improved isocentre reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry

Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...

متن کامل

Quality Control of Conventional Radiology Devices in Selected Hospitals of Khuzestan Province, Iran

Introduction Quality control techniques used to test the components of the radiological system and verify that the equipment is operating satisfactorily. In this study, quality control (QC) assessment of conventional radiology devices was performed in frequently visited radiology centers of Khuzestan province, Iran. Materials and Methods Fifteen conventional radiology devices were examined, bas...

متن کامل

A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy

OBJECTIVE The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. METHODS In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to rece...

متن کامل

Quality Control of Radiography Equipments in Golestan Province of IRAN

Introduction The main goal of this study was to perform quality control test on all radiography units operating in Golestan province of IRAN. Materials and Methods Forty-four X-ray units were examined based on general accepted programs for quality control. Eight parameters including kVp accuracy, kVp reproducibility, mA-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

متن کامل

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2014