Guide Wire Induced Cardiac Tamponade: The Soft J Tip Is Not So Benign
نویسندگان
چکیده
Central venous catheter (CVC) insertion rarely causes cardiac tamponade due to perforation. Although it is a rare complication, it can be lethal if not identified early. We report a case of cardiac tamponade caused by internal jugular (IJ) central venous catheter (CVC) insertion using a soft J-tipped guide wire which is considered safe and rarely implicated with cardiac tamponade. A bedside transthoracic echocardiogram (TTE) revealed a pericardial effusion with tamponade. An emergent bedside pericardiocentesis was done revealing bloody fluid and resulted in clinical stabilization.
منابع مشابه
Surgical management of cardiac tamponade: Is left anterior minithoracotomy really safe and effective?
Objective: Cardiac tamponade is a life-threatening clinical entity that requires an emergency treatment. Cardiac tamponade can be caused both by benign and malignant diseases. A variety of methods have been described for the treatment of these cases from needle-guided pericardiocentesis, balloon-based techniques to surgical pericardiotomy. The Authors report their experience in...
متن کاملحل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال
Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...
متن کاملDiagnosis With Magnetic Resonance Pancreatography
2 Bernath GA, Cogswell TL, Hoffman RG, et al. Influences on the distribution of blood flow during cardiac tamponade in the conscious dog. Circ Res 1987; 60:72–81 3 Kingma JG Jr, Martin J, Rouleau JR. Acute tamponade alters subendoand subepicardial pressure-flow relations differently during vasodilation. Am J Physiol 1994; 267:H133–H138 4 Labovitz AJ, Anthonis DM, Cravens TL, et al. Validation o...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...