Acoustic Radiation Force Impulse (ARFI)--a new modality for the evaluation of liver fibrosis.
نویسندگان
چکیده
AIM to assess the accuracy of transient elastography (TE) and Acoustic Radiation Force Impulse (ARFI) for liver fibrosis assessment, as compared to percutaneous liver biopsy (LB) in patients with chronic hepatitis. PATIENTS AND METHODS Our study included 71 patients (P) (54 with HCV and 17 with HBV chronic hepatitis) in which we compared TE and ARFI to the LB (evaluated according to the Metavir scoring system). RESULTS On LB, from the 71P, 6P (8.4%) had F1, 25P (35.2%) had F2, 24P (33.8%) had F3 and 16P (22.5%) had F4. A direct, strong, linear correlation (Spearman r=0.707) was found between TE measurements and fibrosis (p<0.0001) and a weaker one, between ARFI and fibrosis (rho=0.469; p<0.0001). TE measurements were also correlated with ARFI measurements r=0.532, p<0.0001. By comparing the AUROC curves, TE and ARFI had similar predictive values for the presence of significant fibrosis (F greater or equal to 2 Metavir): AUROC ARFI=0.649, AUROC TE=0.731 (p=0.476); and cirrhosis (F=4 Metavir): AUROC ARFI=0.868, AUROC TE= 0.936 (p=0.294) CONCLUSION LS measurements assessed by means of TE correlate better than those assessed by means of ARFI to the histological fibrosis in patients with HBV and HCV chronic hepatitis. Both methods have excellent predictive values for the presence of cirrhosis.
منابع مشابه
Evaluation of spleen stiffness with acoustic radiation force impulse (ARFI): a comparison with histology in the assessment of liver fibrosis
متن کامل
Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) for the Determination of Liver Stiffness Using Transient Elastography as a Reference in Children.
PURPOSE Transient elastography (Fibroscan(©); (FS)) and acoustic radiation force impulse imaging (ARFI) represent noninvasive, user-friendly and quick methods providing an objective and reproducible measure of liver stiffness. The aim of the study was to evaluate cut-off values and performance of ARFI measurements in children using transient elastography as a reference. METHODS/PATIENTS A tot...
متن کاملUsefulness of acoustic radiation force impulse and fibrotest in liver fibrosis assessment after liver transplant.
UNLABELLED Background and rationale. Acoustic radiation force impulse (ARFI) is a non-invasive tool used in the evaluation of liver fibrosis in HCV positive immune-competent patients. This study aimed to assess the accuracy of ARFI in discriminating liver transplanted patients with different graft fibrosis severity and to verify whether ARFI, eventually combined with non-invasive biochemical t...
متن کاملEffects of patient factors on noninvasive liver stiffness measurement using acoustic radiation force impulse elastography in patients with chronic hepatitis C
BACKGROUND Previous research has shown variation in the effects of patient factors, including hepatic necroinflammatory activity, on liver stiffness measurement (LSM). This prospective study attempts to identify explanatory factors for LSM in patients with chronic hepatitis C (CHC) using acoustic radiation force impulse (ARFI) technology. METHODS A cohort of 127 Taiwanese patients with CHC un...
متن کاملAcoustic Radiation Force Impulse (ARFI) and Transient Elastography (TE) for evaluation of liver fibrosis in HIV-HCV co-infected patients
BACKGROUND Transient elastography (TE) is widely used for non-invasive assessment of liver fibrosis in HIV-HCV co-infected patients. TE, however, cannot determine liver morphology. Acoustic radiation force impulse (ARFI) imaging is a novel procedure enabling assessment of liver fibrosis during a conventional ultrasonographic examination. This study evaluated the correlation between liver fibros...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical ultrasonography
دوره 12 1 شماره
صفحات -
تاریخ انتشار 2010