Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor.

نویسندگان

  • Francesco Valgimigli
  • Fausto Lucarelli
  • Cosimo Scuffi
  • Sara Morandi
  • Iolanda Sposato
چکیده

BACKGROUND The objective of this work was to determine the clinical accuracy of GlucoMen®Day, a new microdialysis-based continuous glucose monitoring system (CGMS) from A. Menarini Diagnostics (Florence, Italy). Accuracy evaluation was performed using continuous glucose-error grid analysis (CG-EGA), as recommended by the Performance Metrics for Continuous Interstitial Glucose Monitoring; Approved Guideline (POCT05-A). METHODS Two independent clinical trials were carried out on patients with types 1 and 2 diabetes mellitus, the glycemic levels of whom were monitored in an in-home setting for 100-hour periods. A new multiparametric algorithm was developed and used to compensate in real-time the GlucoMen®Day signal. The time lag between continuous glucose monitoring (CGM) and reference data was first estimated using the Poincaré plot method. The entire set of CGM/reference data pairs was then evaluated following the CG-EGA criteria, which allowed an estimation of the combined point and rate accuracy stratified by glycemic ranges. RESULTS With an estimated time lag of 11 minutes, the linear regression analysis of the CGM/reference glucose values yielded r = 0.92. The mean absolute error (MAE) was 11.4 mg/dl. The calculated mean absolute rate deviation (MARD) was 0.63 mg/dl/min. The data points falling within the A+B zones of CG-EGA were 100% in hypoglycemia, 95.7% in euglycemia, and 95.2% in hyperglycemia. CONCLUSIONS The GlucoMen®Day system provided reliable, real-time measurement of subcutaneous glucose levels in patients with diabetes for up to 100 hours. The device showed the ability to follow rapid glycemic excursions and detect severe hypoglycemic events accurately. Its accuracy parameters fitted the criteria of the state-of-the-art consensus guideline for CGMS, with highly consistent results from two independent studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GlucoMen Day continuous glucose monitoring system: a screening for enzymatic and electrochemical interferents.

BACKGROUND While most of the common drugs with the potential to interfere with continuous glucose monitoring (CGM) systems are accessible over the counter and can be assumed by CGM patients without medical supervision, many other chemicals are frequently used to treat critically ill patients. Continuous glucose monitoring reading accuracy may also be compromised in patients characterized by abn...

متن کامل

Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

BACKGROUND Despite all commercially available continuous glucose monitoring (CGM) systems being designed to operate in the extracellular interstitial fluid, and even though there is a well-recognized time lag between the interstitial and the venous compartments, the accuracy of the CGM device readings is still evaluated against the glucose concentration in venous blood (VB) samples, thus result...

متن کامل

Intravascular microdialysis as a method for measuring glucose and lactate during and after cardiac surgery.

BACKGROUND The aim was to evaluate intravascular microdialysis as a method for measuring blood glucose and lactate in a clinical setting during and after cardiac surgery. METHODS Ten patients undergoing cardiac surgery were included. A microdialysis catheter was percutaneously placed in the superior vena cava or right atrium. Glucose and lactate values measured by the microdialysis technique ...

متن کامل

Analysis: continuous glucose monitoring in the intensive care unit.

Control of glycemia in hospitalized patients is important; hypoglycemia is associated with increased mortality, and hyperglycemia is associated with adverse outcomes. For these reasons, though no such device is currently available, continuous glucose monitoring (CGM) is an attractive option, especially in the critical care setting. Schierenbeck and coauthors, in this issue of Journal of Diabete...

متن کامل

Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients.

OBJECTIVE We examined the reliability of two continuous glucose sensors in type 1 diabetic patients at night and during rapid glucose excursions and verified the hypothesized nocturnal hypoglycemic drift of the needle-type sensor (CGMSgold) and delay of the microdialysis sensor (GlucoDay). RESEARCH DESIGN AND METHODS Blood was sampled overnight twice per hour in 13 patients. Rapid-acting insu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2010