Split renal function outcome after renal angioplasty in patients with unilateral renal artery stenosis.

نویسندگان

  • A La Batide-Alanore
  • M Azizi
  • M Froissart
  • A Raynaud
  • P F Plouin
چکیده

The general use of bilateral rather than separate renal function evaluation has led to the publication of conflicting results concerning the effect of percutaneous transluminal renal angioplasty (PTRA) on renal function, especially in patients with atherosclerotic renal artery stenosis. The aim of this study was to evaluate prospectively, in standardized conditions, split renal function (SRF) and GFR outcome after successful PTRA, by measuring single kidney GFR with synchronous inulin or (51)Cr-ethylenediaminetetraacetic acid clearance and (99m)Tc-diethylenetriamine pentaacetic acid scintigraphy, in a well-defined population of patients with unilateral renal artery stenosis. Thirty-two consecutive hypertensive patients (18 with atherosclerotic and 14 with dysplastic disease) with significant unilateral stenosis of the main native renal artery (> or = 60%) and normal renal function were included in the study. Renal and angiographic follow-up evaluations were performed 6 mo after PTRA. PTRA alone or combined with stenting (n = 2) was technically successful in all patients. Repeat PTRA was necessary in two patients, evaluated 6 mo after the second PTRA. Six mo after PTRA, total GFR had increased slightly but significantly in the 29 patients with positive lateralization indices. SRF and single-kidney GFR of the stenotic kidney increased significantly, whereas concurrently the GFR and SRF of the nonstenotic kidney decreased significantly. Six mo after successful PTRA reducing renal ischemia, a reversal of both the hypoperfusion of the stenotic side and the hyperperfusion of the nonstenotic side was observed, which was accompanied by a slight increase in total GFR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تاثیر آنژیوپلاستی شریان کلیه بر روی عملکرد دیاستولی در مبتلایان به تنگی شریان کلیه

Abstract Backgraound: Renal artery stenosis is a cause of secondary hypertension. Regarding known complication of this disease and possible positive effects of renal artery angioplasty on diastolic function, this study performed among patients with renal artery stenosis. Methods: This clinical trial, with before and after design, was performed on 35 eligible patients. Patients with renal a...

متن کامل

گزارش یک مورد آنژیوپلاستی و Stent گذاری موفق در درمان تنگی

    Introduction: Renal transplantation has established itself as the treatment of choice for the majority of patients with End stage renal failure(ESRF). Arterial stenosis is the most common vascular complication after kidney transplantation, occurring in approximately 4%-25% of transplant recipients. Case Report: The patient is a 68 year old man with ESRF due to Poly cystic kidney disease(PCK...

متن کامل

MITRAL STENOSIS COMPLICATED BY RENAL ARTERY EMBOLISM

Six patients with mitral stenosis complicated by renal artery embolism studied prospectively are presented. In five patients there was unilateral and in one patient bilateral renal artery involvement. The diagnosis was confirmed by intravenous pyelography, retrograde pyelography, renal angiography, renal scan or a combination of these. All had atrial fibrillation, proteinuria and elevated ...

متن کامل

Split renal function in patients with unilateral atherosclerotic renal artery stenosis—effect of renal angioplasty

OBJECTIVE To evaluate the effect of percutaneous transluminal renal angioplasty (PTRA) on split renal function (SRF) in patients with unilateral atherosclerotic renal artery stenosis (ARAS). METHODS We performed a retrospective analysis of all consecutively examined patients at our centre with significant ARAS undergoing PTRA during 2002-07. A significant ARAS was defined as a lesion with a t...

متن کامل

Renovascular hypertension identified by captopril-induced changes in the renogram.

Radioisotope renography was performed in 21 patients with hypertension and unilateral renal artery stenosis with and without premedication with 25 mg of captopril, and the results were compared with the effect of percutaneous transluminal angioplasty on the blood pressure, assessed 6 weeks after angioplasty. Angioplasty caused a considerable decrease in blood pressure in 15 of the 21 patients. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2001