Conducting Flow Measurement Laboratory Test Work

نویسنده

  • M. B. Kime
چکیده

Mass flow measurement is the basis of most technoeconomic formulations in the chemical industry. This calls for reliable and accurate detection of mass flow. Flow measurement laboratory experiments were conducted using various instruments. These consisted of orifice plates, various sized rotameters, wet gas meter and soap bubble meter. This work was aimed at evaluating appropriate operating conditions and accuracy of the aforementioned devices. The experimental data collected were compared to theoretical predictions from Bernoulli’s equation and calibration curves supplied by the instrument’s manufacturers. The results obtained showed that rotameters were more reliable for measuring high and low flow rates; while soap-bubble meters and wet-gas meters were found to be suitable for measuring low flow rates. The laboratory procedures and findings of the actual work can assist engineering students and professionals in conducting their flow measurement laboratory test work. Keywords—Flow measurement, orifice plates, rotameters, wet gas meter, soap bubble meter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)

For efficient use of water, accurate measurement of flow in (field/laboratory) channels is required for many water resource projects. The present work is aimed to study the flow characteristics of a twin plate weir (two sharp-crested plates are placed one behind the other at some distance) under free and submerged flow conditions. Experiments are performed with four spacing of the twin plate we...

متن کامل

Flow Measurement and Instrumentation

The Lorentz force flowmeter (LFF) is a measuring device utilizing localized static magnetic fields for the non-contact measurement of the flow rate in electrically conducting fluids. In case of highly aggressive or high-temperature conductive fluids, it is difficult to reproduce in a laboratory the conditions typically met in application. Hence, calibration becomes a difficult task. For the LFF...

متن کامل

Experimental Study of Sable Crack Growth in Thin Aluminium Sheet

Recent failure information from research teams in NASA Langley and others has shown that CTOA based fracture models calibrated on large C(T) and M(T) specimens can be transferred successfully to cracked aircraft fuselage structures for the assessment of their residual strength. A major difficulty that could limit the more extensive use of this failure parameter is its experimental measurement e...

متن کامل

Numerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm

One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...

متن کامل

Ultrasonic measurement of gas flow using electrostatic transducers.

Ultrasonic gas flowmeters typically use narrowband piezoelectric transducer arrangements for interrogating the flow of gas in a pipe. In this work, the suitability of broadband electrostatic transducers operating at frequencies of up to 1 MHz for ultrasonic measurement of gas flow has been investigated. The transit time method of ultrasonic gas flow measurement was adopted and experiments were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014