Automatic analysis of pacemaker diagnostic data in the identification of atrial tachyarrhythmias in patients with no prior history of them.
نویسندگان
چکیده
AIMS Modern pacemakers provide a large amount of diagnostic data. Given the limited time available during a pacemaker follow-up visit essential information may be overlooked. This registry was conducted to assess the utility of an expert system that analyses the diagnostic data collected by an implanted pacing device and notifies and advises the physician about suspected technical issues and arrhythmias that need further attention. METHODS Patients with various standard indications for pacing were included in this registry and received single or dual chamber pacemakers. Data were collected and analysed by the expert system during at least two subsequent follow-up visits. The evaluation of this system focused on data obtained from patients with a dual chamber pacing device without prior history of atrial arrhythmias. RESULTS A total number of 239 patients without prior history of atrial tachyarrhythmias were included in this analysis. Atrial tachyarrhythmias were detected in 73 (31%) of these patients. The highest incidence of newly detected arrhythmias occurred in the group of patients with high-degree AV block and VDD pacemakers. Furthermore, newly detected arrhythmias predominantly occurred in the period shortly after implantation. Device programming suggestions by the expert system were adopted in 30% of the cases. Following detection of atrial tachyarrhythmias by the expert system, pharmacological management was adjusted at 71% of the first follow-up visits and at 27% of later follow-up visits. CONCLUSION Results of this registry show that this expert system provides a valuable tool for the detection of atrial tachyarrhythmias during pacemaker follow-up visits.
منابع مشابه
Accuracy of mode switch algorithms for detection of atrial tachyarrhythmias.
INTRODUCTION In patients with permanent pacemakers, mode switching events often are interpreted as surrogate markers for atrial tachyarrhythmias. The aim of this study was to determine the accuracy of automatic mode switching algorithms in patients with permanent pacemakers for the diagnosis of atrial tachyarrhythmias. METHODS AND RESULTS Forty patients with tachycardia-bradycardia syndrome a...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملبررسی نیازهای آموزشی مراقبت از خود بیماران درای دستگاه ضربان ساز دائم در بیمارستان قلب شهید رجائی در سال 73-1372
A field study was made to investigate the learning needs of patients with pacemaker in Shahid Rajaii Heart Hospital's out-patient clinic (1994). A total of 60 patients with pacemaker were selected sequentially from the total population that had a pacemaker and attended the out-patient clinic in shahid Rajaii Hospital. The subjects met the criteria for participating in this study. The tool was a...
متن کاملThe Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead
Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2005