Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation.

نویسندگان

  • Jin Zhang
  • Peter D Olcott
  • Garry Chinn
  • Angela M K Foudray
  • Craig S Levine
چکیده

We studied the performance of a dual-panel positron emission tomography (PET) camera dedicated to breast cancer imaging using Monte Carlo simulation. The PET camera under development has two 10x 15 cm(2) plates that are constructed from arrays of I X 1 X 3 mm(3) LSO crystals coupled to novel ultra-thin (<200 Am) silicon position-sensitive avalanche photodiodes (PSAPD). In this design the photodetectors are configured "edge-on" with respect to incoming photons which encounter a minimum of 2 cm thick of LSO with directly measured photon interaction depth. Simulations predict that this camera will have 10-15% photon sensitivity, for an 8-4 cm panel separation. Detector measurements show approximately 1 mm(3) intrinsic spatial resolution, <12% energy resolution, and approximately 2 ns coincidence time resolution. By performing simulated dual-panel PET studies using a phantom comprising active breast, heart, and torso tissue, count performance was studied as a function of coincident time and energy windows. We also studied visualization of hot spheres of 2.5-4.0 mm diameter and various locations within the simulated breast tissue for 1 X 1 X 3 mm(3), 2 x 2 x 10 mm(3), 3 x 3 x 30 mm(3), and 4 X 4 X 20 mm(3) LSO crystal resolutions and different panel separations. Images were reconstructed by focal plane tomography with attenuation and normalization corrections applied. Simulation results indicate that with an activity concentration ratio of tumor:breast:heart:torso of 10:1:10:1 and 30 s of acquisition time, only the dual-plate PET camera comprising 1 X 1 X 3 mm(3) crystals could resolve 2.5 mm diameter spheres with an average peak-to-valley ratio of 1.3.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling

Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...

متن کامل

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Validation and evaluation of a GATE model for MAMMI PET scanner

Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard.  Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2007