Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.
نویسندگان
چکیده
PURPOSE To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurements were obtained with a modified commercial scanning laser polarimeter (GDx Nerve Fiber Analyzer; Laser Diagnostic Technologies, Inc., San Diego, CA) so that corneal birefringence could be corrected on a subject-specific variable basis. The shape of the RNFL thickness double-hump pattern was analyzed by Fourier analysis of polarimetry data. Fourier coefficients and GDx parameters were compared between the two groups. A linear discriminant function was developed to identify and combine the most useful Fourier coefficients to separate the two groups. Receiver operating characteristic (ROC) curves were obtained for each measurement, and sensitivity values (at fixed specificities) were calculated. RESULTS The Fourier-based linear discriminant function (LDF Fourier) resulted in a sensitivity of 84% for a specificity set at 92%. For similar specificity, the GDx software-provided parameters had sensitivities ranging from 24% to 69%. The area under ROC curve for the LDF Fourier was 0.949, significantly larger than the ROC curve area for the single best GDx software-provided parameter, superior average (0.870). CONCLUSIONS The combination of Fourier RNFL thickness measures in an LDF, obtained using SLP with variable corneal compensation, improved the ability to discriminate glaucomatous from healthy eyes, compared with the GDx software-provided parameters.
منابع مشابه
Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes.
OBJECTIVE To compare the association between scanning laser polarimetry (SLP) retinal nerve fiber layer (RNFL) measurements and automated perimetry sensitivity using both SLP manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude and corneal polarization axis values. METHODS An SLP was modified to enable the measurement of corneal polarization magnitude and co...
متن کاملIntraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients
Purpose: To quantify the intraobserver reproducibility of retinal nerve fiber layer (RNFL) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. Methods: Twenty-six eyes of 26 glaucoma suspect patients were included. Complete ophthalmologic examination and standard automated perimetry were performed for all of them. RNFL measurements were...
متن کاملLongitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation.
OBJECTIVE To investigate the longitudinal corneal birefringence (corneal polarization axis [CPA] and corneal polarization magnitude [CPM]) variability in scanning laser polarimetry with variable corneal compensation and its effect on retinal nerve fiber layer measurements. Method We analyzed scanning laser polarimetry images obtained every 6 months for 3.2 years in 16 healthy eyes, 38 eyes with...
متن کاملAssessment of the retinal nerve fiber layer of the normal and glaucomatous monkey with scanning laser polarimetry.
PURPOSE To describe and test a method for assessment of the monkey retinal nerve fiber layer (RNFL) with scanning laser polarimetry. METHODS A scanning laser polarimeter was modified to accommodate a variable corneal polarization compensator. Corneal polarization magnitude (CPM) and corneal polarization axis (CPA) of the anterior segment birefringence of normal and glaucomatous cynomolgus mon...
متن کاملScanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes.
PURPOSE To evaluate the relationship between visual function and retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry with variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). DESIGN Cross-sectional analysis of normal and glaucomatous eyes in a tertiary care academic referral practice. METHODS A commercial GDx nerve fiber analyzer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 6 شماره
صفحات -
تاریخ انتشار 2003