Echoplanar chemical shift imaging.

نویسندگان

  • A R Guimaraes
  • J R Baker
  • B G Jenkins
  • P L Lee
  • R M Weisskoff
  • B R Rosen
  • R G González
چکیده

A novel method of chemical shift imaging utilizing echoplanar imaging (EPI) has been developed for the purpose of improving the spatial resolution of metabolite images for the specific goal of high spatial resolution mapping of neuronal content. An EPI sequence was modified to allow temporal offsets of the 180 degree refocusing pulse that encode the chemical shift information into the phase of the signal. Implementation of this method on 1.5 and 3 T human imagers has resulted in images of N-acetyl aspartate in humans with spatial resolution of 360 microl and signal-to-noise ratio approximately 7:1 in less than 13 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of high-resolution echoplanar spectroscopic imaging for structural imaging.

Echoplanar spectroscopic imaging (EPSI) was introduced as a fast alternative for spectroscopic imaging and has been recently implemented on clinical scanners. With further advances in gradient hardware and processing strategies, EPSI can be used to obtain spectroscopic images whose spatial resolution parallels that of conventional anatomic images within clinically acceptable acquisition time. T...

متن کامل

Multi-Echo based Correlated Spectroscopic Imaging

Introduction – Despite the many advantages of Chemical Shift Imaging (CSI) [1] over ordinary single voxel spectroscopy, its onedimensional (1D) spectra are still limited by severe spectral overlap, which can complicate quantification of metabolites. Twodimensional Magnetic Resonance Spectroscopy (2D MRS) aims to alleviate the quantification problems due to spectral overlap by pushing resonances...

متن کامل

"Pitfalls in Diffusion: What Artifacts Should I Worry About?"

This presentation covers the sources of many common diffusion image artifacts. Some of these arise from the limitations of single-shot echoplanar imaging (EPI), including low spatial resolution, blurring effects of T2* decay and T2 decay occurring during image readout, and sensitivity to artifacts due to Nyquist ghosting, chemical shift, magnetic field inhomogeneity, and local susceptibility ef...

متن کامل

Assessment of response of uterine fibroids and myometrium to embolization using diffusion-weighted echoplanar MR imaging.

Our objective was to evaluate the role of echoplanar diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps in the assessment of response of uterine fibroids and myometrium to uterine fibroid embolization (UFE). We evaluated 32 fibroids in 11 patients treated with UFE. Treated lesions had low ADC values compared to untreated lesions. Furthermore, ADC values of the myomet...

متن کامل

Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging.

Improved data acquisition and processing strategies for blood oxygenation level-dependent (BOLD)-contrast functional magnetic resonance imaging (fMRI), which enhance the functional contrast-to-noise ratio (CNR) by sampling multiple echo times in a single shot, are described. The dependence of the CNR on T2*, the image encoding time, and the number of sampled echo times are investigated for expo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 1999