Left ventricular mass: manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs.

نویسندگان

  • Christopher J François
  • David S Fieno
  • Stephanie M Shors
  • J Paul Finn
چکیده

PURPOSE To evaluate the accuracy of manually and automatically segmented true fast imaging with steady-state precession (FISP) and fast low-angle shot (FLASH) cine magnetic resonance (MR) imaging in the determination of left ventricular (LV) mass. MATERIALS AND METHODS Nine dogs and five pigs underwent cine MR imaging of the entire LV from base to apex. Manual and automatic segmentation times were recorded, and LV masses determined with each were compared with each other and with the true LV mass at autopsy. Estimated mass and true mass at autopsy were compared by calculating the correlation coefficient and the mean difference between the two for each MR sequence and segmentation method. RESULTS True LV mass at autopsy correlated well with masses determined with manual and automatic contours on true FISP MR images. Mean differences between true LV mass and masses determined from manual contours on true FISP and FLASH images were -0.8 g +/- 2.6 and 3.7 g +/- 6.8, respectively. When manually drawn end-diastolic contours were automatically propagated to end systole, mean differences were 2.0 g +/- 3.6 (P =.05) and 9.1 g +/- 6.5 (P <.05) for true FISP and FLASH images, respectively. For automatic contours, mean differences were 10.6 g +/- 8.5 (P <.05) and 27.7 g +/- 13.4 (P <.05) for true FISP and FLASH images, respectively. Mean automatic segmentation time was six times less than mean manual segmentation time. CONCLUSION LV mass was determined most accurately by using manual contours on true FISP images. In these animal models, fully automatic segmentation of true FISP images was performed in one-sixth of the time of manual segmentation and yielded LV masses with a mean error of approximately 5% of true LV mass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without br...

متن کامل

A Method for Body Fat Composition Analysis in Abdominal Magnetic Resonance Images Via Self-Organizing Map Neural Network

Introduction: The present study aimed to suggest an unsupervised method for the segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in axial magnetic resonance (MR) images of the abdomen. Materials and Methods: A self-organizing map (SOM) neural network was designed to segment the adipose tissue from other tissues in the MR images. The segmentation of SAT and VA...

متن کامل

Fully automatic segmentation of short and long axis cine cardiac MR

Introduction Quantitative analysis of cardiac function requires delineation of the left ventricle (LV) in cine cardiac MR (CMR). Typically, this is done using short-axis (SA) images, however, acquisition of several long-axis (LA) views has become quite common. The latter can be used for the accurate and reproducible determination of the basal SA slice, known as one of the major inter-observer v...

متن کامل

Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection.

The purpose of this study was to evaluate an automatic boundary detection algorithm of the left ventricle on magnetic resonance (MR) short-axis images with the essential restriction of no manual corrections. The study comprised 13 patients (nine men, four women) and 12 healthy volunteers (11 men, one woman), and institutional review board approval and informed consent were obtained. The outline...

متن کامل

Measurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images

Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 230 2  شماره 

صفحات  -

تاریخ انتشار 2004