The impact of central corneal thickness on intraocular pressure among Ethiopian glaucoma patients: a cross-sectional study

نویسنده

  • Yeshigeta Gelaw
چکیده

BACKGROUND Raised intraocular pressure (IOP) is the only causal risk factor for glaucoma that can be therapeutically manipulated to change the course of the disease process. Though Goldman applanation tonometry (GAT) is the "gold standard" for IOP measurement, readings of IOP with GAT are affected by central corneal thickness (CCT). The aim of this study is to determine the impact of CCT on IOP among Ethiopian glaucoma patients. METHODS It was a multicenter cross-sectional study and all glaucoma patients visiting their respective eye clinic during the study period were included. A total of 199 randomly selected glaucomatous eyes from 199 patients aged 18 years and above were employed. The CCT was measured by OcuScan™ RxP Ophthalmic Ultrasound and IOP was measured with Goldmann applanation tonometer. Linear regression and bivariate correlation analysis were carried out and level of significance was taken at 5%. RESULTS The mean IOP was 19.46(± 7.05) mmHg and mean CCT was 508.07(± 33.26) μm. The mean IOP for primary open angle glaucoma (POAG), ocular hypertension (OHT), normal tension glaucoma (NTG), pseudoexfoliative glaucoma (PXG) and primary chronic angle closure glaucoma (PCAG) patients was 19.22 mmHg, 21.39 mmHg, 14.33 mmHg, 33.25 mmHg and 14.75 mmHg respectively. The mean CCT values were 502.24 μm (POAG), 524.32 μm (OHT), 500.75 μm (NTG), 579.00 μm (PXG) and 530.25 μm (PCAG). Age of the patient and glaucoma surgery had an influence on corneal thickness. A positive relationship was found between CCT and IOP (p<0.001). CONCLUSIONS The mean CCT of Ethiopian glaucoma patients is thin in comparison to other ethnic groups and patients with OHT have thicker corneas than POAG patients. Hence determination of CCT for each patient is necessary in the up-to-date glaucoma management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

The influence of central corneal thickness on intraocular pressure measured by goldmann applanation tonometry among selected Ethiopian communities.

BACKGROUND Estimates of intraocular pressure (IOP) are influenced directly by the central corneal thickness (CCT). We assume and apply a single value for CCT (520 μm) in applanation tonometry estimates, although there is compelling evidence that CCT varies between individuals. OBJECTIVE To determine the influence of CCT and other factors on IOP among Ethiopians. METHODS A cross sectional st...

متن کامل

Corneal thickness in congenital glaucoma.

Central corneal thickness is very important measurement in glaucoma treatment because it influences the eye pressure measurements. A thinner cornea gives us artifactually lower intraocular pressure and a thicker cornea gives higher intraocular pressure reading, so it has to be corrected in both cases. The aim of this study is to compare central corneal thickness between congenital glaucoma pati...

متن کامل

What is the Real Cause of Glaucoma?

Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...

متن کامل

Correlation between central corneal thickness and intraocular pressure peak and fluctuation during the water drinking test in glaucoma patients

OBJECTIVE To investigate the correlation between central corneal thickness and outflow facility assessed by intraocular pressure peak and fluctuation during the water drinking test. METHODS Fifty-five newly diagnosed primary open-angle glaucoma patients submitted to central corneal thickness measurements and water drinking test were enrolled in this retrospective study.;. Patients were divide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012