Open-path, quantum cascade-laser-based sensor for high-resolution atmospheric ammonia measurements
نویسندگان
چکیده
We demonstrate a compact, open-path, quantum cascade-laser-based atmospheric ammonia sensor operating at 9.06 μm for high-sensitivity, high temporal resolution, ground-based measurements. Atmospheric ammonia (NH3) is a gas-phase precursor to fine particulate matter, with implications for air quality and climate change. Currently, NH3 sensing challenges have led to a lack of widespread in situ measurements. Our open-path sensor configuration minimizes sampling artifacts associated with NH3 surface adsorption onto inlet tubing and reduced pressure sampling cells, as well as condensed-phase partitioning ambiguities. Multi-harmonic wavelength modulation spectroscopy allows for selective and sensitive detection of atmospheric pressurebroadened absorption features. An in-line ethylene reference cell provides real-time calibration (±20 % accuracy) and normalization for instrument drift under rapidly changing field conditions. The sensor has a sensitivity and noise-equivalent limit (1σ ) of 0.15 ppbv NH3 at 10 Hz, a mass of ∼ 5 kg and consumes ∼ 50 W of electrical power. The total uncertainty in NH3 measurements is 0.20 ppbv NH3± 10 %, based on a spectroscopic calibration method. Field performance of this open-path NH3 sensor is demonstrated, with 10 Hz time resolution and a large dynamic response for in situ NH3 measurements. This sensor provides the capabilities for improved in situ gas-phase NH3 sensing relevant for emission source characterization and flux measurements.
منابع مشابه
Compact and portable open-path sensor for simultaneous measurements of atmospheric N2O and CO using a quantum cascade laser.
A compact and portable open-path sensor for simultaneous detection of atmospheric N(2)O and CO has been developed with a 4.5 μm quantum cascade laser (QCL). An in-line acetylene (C(2)H(2)) gas reference cell allows for continuous monitoring of the sensor drift and calibration in rapidly changing field environments and thereby allows for open-path detection at high precision and stability. Wavel...
متن کاملChirped Laser Dispersion Spectroscopy for Remote Open-Path Trace-Gas Sensing
In this paper we present a prototype instrument for remote open-path detection of nitrous oxide. The sensor is based on a 4.53 μm quantum cascade laser and uses the chirped laser dispersion spectroscopy (CLaDS) technique for molecular concentration measurements. To the best of our knowledge this is the first demonstration of open-path laser-based trace-gas detection using a molecular dispersion...
متن کاملReal time ammonia detection in exhaled human breath using a distributed feedback quantum cascade laser based sensor
A continuous wave, thermoelectrically cooled, distributed feedback quantum cascade laser (DFB-QCL) based sensor platform for the quantitative detection of ammonia (NH3) concentrations present in exhaled human breath is reported. The NH3 concentration measurements are performed with a 2f wavelength modulation quartz enhanced photoacoustic spectroscopy (QEPAS) technique, which is very well suited...
متن کاملTransportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum-cascade distributed feedback laser.
A compact ammonia sensor based on a 10-microm single-frequency, thermoelectrically cooled, pulsed quantum-cascade laser with an embedded distributed feedback structure has been developed. To measure NH3 concentrations, we scanned the laser over two absorption lines of its fundamental v2 band. A sensitivity of better than 0.3 parts per million was achieved with just a 1-m optical path length. Th...
متن کاملMid-infrared trace-gas sensing with a quasi- continuous-wave Peltier-cooled distributed feedback quantum cascade laser
A recently developed distributed feedback quantum cascade laser (QCL) capable of thermoelectric-cooled (TEC) continuous-wave (cw) operation and emitting at ∼ 9 μm is used to perform laser chemical sensing by tunable infrared spectroscopy. A quasi-continuous-wave mode of operation relying on long current pulses (∼ 5 Hz, ∼ 50% duty cycle) is utilized rather than pure cw operation in order to exte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014