Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery

نویسندگان

  • Sang Yeop Lee
  • Hyoung Won Bae
  • Hee Jung Kwon
  • Gong Je Seong
  • Chan Yun Kim
چکیده

The utility of Goldmann applanation tonometry (GAT) for monitoring intraocular pressure (IOP) in open-angle glaucoma (OAG) patients with a history of laser refractive surgery was investigated by comparing IOP fluctuations measured using GAT and dynamic contour tonometry (DCT) on the same day. In this retrospective study, patients were divided into one of two subgroups according to IOP fluctuation values using GAT: 43 eyes in the low IOP fluctuation group (LIFG [GAT fluctuation ≤1.7 mmHg]); and 55 eyes in the high IOP fluctuation group (HIFG [GAT fluctuation >1.7 mmHg]). IOP fluctuation was defined as the standard deviation of all IOP values during follow-up. IOP parameters using GAT were compared with those of DCT. Correlation analyses were performed among IOP parameters, and between IOP fluctuation and associated factors including central corneal thickness, corneal curvature, and axial length. All IOP parameters demonstrated significantly high values in the HIFG compared with those in the LIFG. Mean and peak IOP using DCT were significantly higher than those using GAT in both groups. However, there were no significant differences in IOP fluctuation and reduction using both tonometry methods in the HIFG (p = 0.946 and p = 0.986, respectively). Bland-Altman analysis revealed similar fluctuations using GAT and DCT. In multivariate analyses, there was a significant correlation between fluctuations using GAT and DCT in the HIFG (p = 0.043). These results suggest that IOP monitoring using GAT is a reliable method of monitoring IOP change in glaucoma patients with a history of laser refractive surgery, especially those exhibiting high IOP fluctuation. Nevertheless, several factors, including central corneal thickness, corneal curvature, and axial length, should be considered when using GAT for IOP monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

History and Clinical Validation of the PASCAL Dynamic Contour Tonometer

Will Goldmann applanation tonometry, the age old “gold standard” of intraocular pressure (IOP) measurement, be replaced with newer methods? One of the newer methods of IOP measurement is PASCAL dynamic contour tonometry (DCT). A review of the history, scientific principles, clinical validation and clinical utility of DCT is presented.

متن کامل

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل