Point-of-care Blood Coagulation Monitoring Using Lateral Flow Device

نویسندگان

  • Hua Li
  • Daewoo Han
  • Giovanni M. Pauletti
  • Andrew J. Steckl
چکیده

A simple and affordable method of evaluating blood coagulation ability using microfluidic paperbased lateral flow assay (LFA) device is reported. Rabbit whole blood treated with citrate as anticoagulant was used in experiments. Re-establishment of blood coagulation cascade and creation of different coagulation abilities were achieved by adding CaCl2 solutions of varying concentrations. Since viscosity change of blood depends on its coagulation ability, travel distance of red blood cells (RBC) on nitrocellulose membrane can be used as an indicator of blood clotting time. RBC travel distance is found to decrease linearly with increasing CaCl2 concentration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood coagulation screening using a paper-based microfluidic lateral flow device.

A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LFA) device for point-of-care (POC) and self-monitoring screening is reported. The device utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent co...

متن کامل

Flow reproducibility of whole blood and other bodily fluids in simplified no reaction lateral flow assay devices.

The "no reaction" lateral flow assay (nrLFA) uses a simplified LFA structure with no conjugate pad and no stored reagents. In the nrLFA, the capillary-based transport time or distance is the key indicator, rather than the outcome of a biochemical reaction. Hence, the calibration and reproducibility of the nrLFA device are critical. The capillary flow properties of several membrane types (nitroc...

متن کامل

Development of a fluorescent method for detecting the onset of coagulation in human plasma on microstructured lateral flow platforms.

Microfluidic devices and microsystems have been used to develop blood coagulation monitoring devices for point of care diagnostic use. However, many of them suffer from inherent variability and imprecision, partly due to the fact that they only detect changes in bulk clotting properties and do not reflect the microscopic nature of blood coagulation. This work demonstrates microstructured latera...

متن کامل

A Miniaturized Hemoretractometer for Blood Clot Retraction Testing.

Blood coagulation is a critical hemostatic process that must be properly regulated to maintain a delicate balance between bleeding and clotting. Disorders of blood coagulation can expose patients to the risk of either bleeding disorders or thrombotic diseases. Coagulation diagnostics using whole blood is very promising for assessing the complexity of the coagulation system and for global measur...

متن کامل

گزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications

 Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014