Automatic image acquisition, calibration and montage assembly for biological X-ray microscopy.

نویسندگان

  • B W Loo
  • W Meyer-Ilse
  • S S Rothman
چکیده

We describe a system for the automatic acquisition and processing of digital images in a high-resolution X-ray microscope, including the formation of large-field high-resolution image montages. A computer-controlled sample positioning stage provides approximate coordinates for each high-resolution subimage. Individual subimages are corrected to compensate for time-varying, non-uniform illumination and CCD-related artefacts. They are then automatically assembled into a montage. The montage assembly algorithm is designed to use the overlap between each subimage and multiple neighbours to improve the performance of the registration step and the fidelity of the result. This is accomplished by explicit use of recorded stage positions, optimized ordering of subimage insertion, and registration of subimages to the developing montage. Using this procedure registration errors are below the resolution limit of the microscope (43 nm). The image produced is a seamless, large-field montage at full resolution, assembled automatically without human intervention. Beyond this, it is also an accurate X-ray transmission map that allows the quantitative measurement of anatomical and chemical features of the sample. Applying these tools to a biological problem, we have conducted the largest X-ray microscopical study to date.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photometric calibration for quantitative spectral microscopy under transmitted illumination.

Over the past decade, there have been significant developments in the mechanisms for examination of biological and material samples. These developments exploit techniques in light microscopy to elucidate specific parts of cells and tissues, as well as inorganic particles. In recent years, spectral microscopy has become more prevalent for characterization of samples. Simultaneously, sensor techn...

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

A MicroCT Guided Fluorescence Tomography System for Small Animal

.................................................................................................................................................. I ACKNOWLEDGEMENTS.........................................................................................................................II LIST OF TABLES ................................................................................................

متن کامل

Calibration of High-Resolution X-Ray Tomography With Atomic Force Microscopy

For two-dimensional x-ray imaging of thin films, the technique of scanning transmission x-ray microscopy (STXM) has achieved images with feature sizes as small as 40 nm in recent years. However, calibration of three-dimensional tomographic images that are produced with STXM data at this scale has not yet been described in the scientific literature, and the calibration procedure has novel proble...

متن کامل

Implementation of a Data Acquisition System for 2×2 Fiber Optic Taper Array Coupled Digital X-ray Detector

Fiber optic taper (FOP) array coupled digital x-ray detector can be an ideal choice for large area high resolution x-ray imaging, but its data acquisition system is a challenge, for the reasons such as restrictions of hardware design due to the shape of the FOP array, long distance control requirement in x-ray environment, and arrangement of data transmission sequence among multiple CCD/CMOS im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of microscopy

دوره 197 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2000