High-resolution HbA(1c) separation and hemoglobinopathy detection with capillary electrophoresis.

نویسنده

  • Eloísa Urrechaga
چکیده

The CAPILLARYS HbA(1c) kit used on the CAPILLARYS 2 Flex Piercing system is designed for separating and quantifying the HbA(1c) fraction of hemoglobin while detecting hemoglobin variants and HbA(2). The aim of this study was to assess the performance of this new capillary electrophoresis kit for routine HbA(1c) quantification for patients with diabetes. The reliability of the system for HbA(2) measurement was also assessed. Precision, correlation, and linearity studies were performed. The effect of hemoglobin concentration and the presence of coexistent interfering substances were evaluated. The results were found to be accurate and linear in the clinically significant analytic range with excellent precision (mean interassay coefficient of variation of 0.7%). HbA(1c) measurement is independent of the presence of common hemoglobin interferences for HbA(1c) quantification and the total concentration of hemoglobin. Moreover, the technique provides a rapid and reliable separation of HbA(2). The measurement is reproducible and the results in β-thalassemia carriers were statistically different from those in noncarriers. Thus, this technique might be used for β-thalassemia detection. Given the short time of the analysis and the high throughput, this is a suitable system for the control of diabetes and the detection of hemoglobinopathies in laboratories with high workflow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Haemoglobin J-Baltimore can be detected by HbA1c electropherogram but with underestimated HbA1c value

Glycated haemoglobin (HbA(1c)) is considered the gold standard for assessing diabetes compensation and treatment. In addition, fortuitous detection of haemoglobin variants during HbA1c measurement is not rare. Recently, two publications reported different conclusions on accuracy of HbA(1c) value using capillary electrophoresis method in presence of haemoglobin J-Baltimore (HbJ).
Here we describ...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Hemoglobin D is the Commonest Hemoglobinopathy in the North of Iran

Abstract         Background and Objective: Normal hemoglobin (Hb) is formed of a heme group and a protein group known as globin. Globin is made of four polypeptide chains and in hemoglobinopathies, the structure of one of these four polypeptide chain becomes abnormal. Cellulose acetate method is a common way to differentiate haemoglobinopathies. Inabilit...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 138 3  شماره 

صفحات  -

تاریخ انتشار 2012