Preparation of whole blood for liquid scintillation counting.

نویسنده

  • P A Moore
چکیده

Liquid scintillation counting of 3H-labeled whole-blood samples is severely impaired owing to quenching by blood pigments. In this study, dry oxidation and chemical solubilization followed by decolorization were the two general methods used to eliminate color quenching. Three blood volumes were examined: 0.25, 0.50, and 1.0 mL. Dry oxidation yielded complete recoveries of 3H label with counting efficiencies greater than 30% for up to 1.0 mL of blood. Although blood volumes larger than 0.25 mL can be used with chemical solubilization and decolorization, treatment of 0.25 mL of blood gave the highest counting efficiencies, with count rates comparable to those for 1.0-mL samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cocktails for Liquid Scintillation Counting

It is most important to assure 4 π−geometry in liquid scintillation counting for accurate results1. Usually this can be assured by dissolution of the sample in an appropriate cocktail. The cocktail does not only contain a solvent but also at least one scintillator and surfactants for aqueous samples because aqueous samples are completely insoluble in the pure organic solvents and scintillators....

متن کامل

Distribution of [14C]aztreonam in rat tissue.

[14C]aztreonam was administered intramuscularly (50 mg/kg) to male and female rats. Groups of 10 rats (five male and five female) were sacrificed at 0.25, 2, 6, and 24 h after dosing. Blood and various tissues were removed from six rats (three male and three female) in each group for determination of total radioactivity and unchanged aztreonam by liquid scintillation counting and thin-layer rad...

متن کامل

Some Factors Affecting Alpha Particle Detection In Liquid Scintillation Spectrometry

Pulse shape analyzers have been introduced in commercial liquid scintillation counters, such as the WaIlac 1220 QuantulusTM and 1219 SM, enabling separation of alpha particle spectra from other types of radiation in a single measurement and making ultra sensitive alpha counting possible. Background count rates as low as one count per day for 214Po in a teflon vial are achievable while still ret...

متن کامل

Cerenkov Counting Performance on the TopCount Microplate Scintillation and Luminescence Counter

The TopCount Microplate Scintillation and Luminescence Counter has been widely used in biopharmaceutical assays involving both radionuclide and luminescence measurement. A new feature allows the use of TopCount for measuring a high energy beta emitter such as P by Cerenkov counting, a well-known measurement technique that has the main advantage of not requiring the addition of scintillation coc...

متن کامل

Simultaneous determination of radium and uranium activities in natural water samples using liquid scintillation counting

The determination of radium and/or uranium concentrations in natural waters is useful in a wide range of environmental studies. In this work, a low-background liquid scintillation system (Wallac, Quantulus 1220) was used to determine simultaneously 226Ra and uranium (total) activities in natural water samples. Sample preparation involved filtration and 1 : 10 concentration by evaporation. Then,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 1981