The Nordic Trueness Project 2002: use of reference measurement procedure values in a general clinical chemistry survey.
نویسندگان
چکیده
Up to 136 laboratories participated in a joint effort to assess the trueness of routine measurements for 14 serum components. An unmodified, fresh-frozen human serum ("IMEP-17 Material 1"), produced for an international inter-laboratory comparison, served as the "master material". The serum had assigned values of the highest available metrological quality, and is assumed to involve no or negligible commutability problems. The material was used in the assignment of traceable values to two other reference sera, "CAL" and "X", through parallel measurements on the three materials according to a common protocol. In this transfer process, uncertainty estimates were provided for all values. The material CAL had been supplied with reference measurement procedure values in 1997, and the two sets of assigned values agreed well. A lyophilized control serum "HK02" was also included in the routine analysis series. It, too, had assigned values based on reference measurement procedures. Significant matrix effects were found. The project has provided: Assigned traceable values for 14 components in a fresh-frozen serum, available to Nordic laboratories for the coming years as "NFKK reference serum X"; Confirmation of earlier assigned reference measurement procedure values for a number of components in CAL, the main calibrator in the Nordic Reference Interval project (NORIP). The transferred values will now serve as the primary reference.; Evidence of long-term stability ( > or = 5 years) of the fresh-frozen serum CAL when stored at -80 degrees C; Evidence of substantial matrix effects in the processed serum HK02. The findings should be used to discuss to what extent reference measurement procedure values are useful and cost-efficient for this type of material.
منابع مشابه
State of the art in trueness and interlaboratory harmonization for 10 analytes in general clinical chemistry.
CONTEXT Harmonization and standardization of results among different clinical laboratories is necessary for clinical practice guidelines to be established. OBJECTIVE To evaluate the state of the art in measuring 10 routine chemistry analytes. DESIGN A specimen prepared as off-the-clot pooled sera and 4 conventionally prepared specimens were sent to participants in the College of American Pa...
متن کاملFeasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.
BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...
متن کاملAssessment of the Trueness and Inter-Laboratory Precision of Routine Uric Acid Assays Using 4 Frozen Pooled Serum Samples Measured by the Japan Society of Clinical Chemistry's HPLC Method
BACKGROUND Reference procedures are required for evaluating the accuracy of routine analytical systems for uric acid (UA). External quality assessment (EQA) for UA has only been conducted with quality controls in China, and the results have not been published. This study was designed to investigate both the trueness and inter-laboratory precision of UA measurements among routine analytical syst...
متن کاملTrueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. An international study in the framework of the EC4 creatinine standardization working group.
BACKGROUND The European In Vitro Diagnostics (IVD) directive requires traceability to reference methods and materials of analytes. It is a task of the profession to verify the trueness of results and IVD compatibility. METHODS The results of a trueness verification study by the European Communities Confederation of Clinical Chemistry (EC4) working group on creatinine standardization are descr...
متن کاملTrueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum: an international study in the EC4 framework of the Calibration 2000 project.
BACKGROUND The in vitro diagnostics directive of the European Union requires traceability to higher order reference measurement procedures and materials for analytes in assuring the result trueness and comparability of laboratory measurements. Manufacturers must ensure that the systems they market are calibrated against available reference systems. Validation of metrologically traceable calibra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scandinavian journal of clinical and laboratory investigation
دوره 64 4 شماره
صفحات -
تاریخ انتشار 2004