Immunodiagnosis of human granulocytic ehrlichiosis by using culture-derived human isolates.

نویسندگان

  • M D Ravyn
  • J L Goodman
  • C B Kodner
  • D K Westad
  • L A Coleman
  • S M Engstrom
  • C M Nelson
  • R C Johnson
چکیده

Human granulocytic ehrlichiosis (HGE) is an emerging infection caused by an Ehrlichia species closely related to Ehrlichia equi and Ehrlichia phagocytophila. Recent advances in the isolation and cultivation of this organism have allowed us to develop an immunofluorescence assay (IFA), enzyme immunoassay (EIA), and Western immunoblotting (WB) using HL-60 cell culture-derived human isolates. Antibody was detected in sera from culture-confirmed HGE patients by IFA and EIA, and these samples were reactive when analyzed by immunoblot analysis. HGE patient sera had high antibody titers and did not react with uninfected HL-60 cells. When IFA, EIA, and WB were used to analyze sera from healthy donors or those with a range of other disorders, including infections caused by Ehrlichia chaffeensis, Rickettsia rickettsii, and Coxiella burnetti, no significant cross-reactivity could be detected by EIA or immunoblot analysis with the exception of two of four serum samples from R. rickettsii-infected patients that were reactive by IFA only. Sera from HGE patients did not significantly cross-react in serologic tests for Borrelia burgdorferi. Using sera from patients previously enrolled in two clinical trials of treatment for early Lyme disease, we evaluated a two-step approach for estimation of the seroprevalence of antibodies reactive with the etiologic agent of HGE. On the basis of the immunoblot assay results for sera from culture-confirmed HGE patients, WB was used to confirm the specificity of the antibody detected by EIA and IFA. EIA was found to be superior to IFA in the ability to detect WB-confirmed antibodies to the HGE agent. When EIA and WB were used, 56 (19.9%) patients with early Lyme disease (n = 281) had either specific immunoglobulin M (IgM) or IgG antibodies; 38 patients (13.5%) had IgM only, 6 (2.1%) had IgG only, and 12 (4.3%) had both IgM and IgG. Therefore, Lyme disease patients are at high potential risk for exposure to Ehrlichia. Analysis by immunoblotting of serial samples from persons with culture-confirmed HGE or patients with Lyme disease and antibodies to the agent of HGE revealed a reproducible pattern of the immune response to specific antigens. These samples confirmed the importance of the 42- to 45-kDa antigens as early, persistent, and specific markers of HGE infection. Other significant immunogenic proteins appear at 20, 21, 28, 30, and 60 kDa. Use of the two-test method of screening by EIA and confirming the specificity by WB appears to offer a sound approach to the clinical immunodiagnosis of HGE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental inoculation with human granulocytic Ehrlichia agent derived from high- and low-passage cell culture in horses.

We report the successful infection throughout intravenous inoculation with low and high passage of in vitro-grown human granulocytic ehrlichiosis (HGE) agent in horses. Differences in disease severity but not in incubation time, hematological changes, PCR detection, ehrlichial load, seroconversion time, and titer range were noted between horses infected with a low and a high passage of in vitro...

متن کامل

Comparison of the nucleotide sequences of 16S rRNA, 444 Ep-ank, and groESL heat shock operon genes in naturally occurring Ehrlichia equi and human granulocytic ehrlichiosis agent isolates from Northern California.

We examined 11 naturally occurring isolates of Ehrlichia equi in horses and two human granulocytic ehrlichiosis agent isolates in California for sequence diversity in three genes. Ehrlichia equi isolates were from Sierra (n = 6), Mendocino (n = 3), Sonoma (n = 1), and Marin (n = 1) counties, and human granulocytic ehrlichiosis (HGE) agent isolates were obtained from Humboldt county. PCR with sp...

متن کامل

Survival of the human granulocytic ehrlichiosis agent under refrigeration conditions.

The human granulocytic ehrlichiosis (HGE) agent in infected blood specimens remained viable during refrigeration at 4 degrees C for up to 18 days. These findings suggest that blood specimens submitted for culture may withstand transportation to a remote laboratory. HGE should be added to the list of infections potentially transmitted by blood transfusion.

متن کامل

Antigenic diversity of granulocytic Ehrlichia isolates from humans in Wisconsin and New York and a horse in California.

The agent of human granulocytic ehrlichiosis (HGE), Ehrlichia phagocytophila, and Ehrlichia equi are very similar. HGE is of variable severity. Genetic and antigenic differences among 3 human isolates (Webster, Spooner, and NY-8) and 1 horse isolate (MRK) were evaluated. The 16S rRNA gene sequences were identical in all human isolates. By use of 5 homologous antisera from these 3 humans and 1 h...

متن کامل

An indirect immunofluorescence assay using a cell culture-derived antigen for detection of antibodies to the agent of human granulocytic ehrlichiosis.

An indirect immunofluorescence assay for the detection of human antibodies to the agent of human granulocytic ehrlichiosis (HGE) was developed and standardized. Antigen was prepared from a human promyelocytic leukemia cell line (HL-60) infected with a tick-derived isolate of the HGE agent (USG3). Suitable antigen presentation and preservation of cellular morphology were obtained when infected c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 1998