A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry.

نویسندگان

  • Berndt Zur
  • Andreas Hornung
  • Johannes Breuer
  • Ulrike Doll
  • Christine Bernhardt
  • Michael Ludwig
  • Birgit Stoffel-Wagner
چکیده

BACKGROUND A 4-year-old boy and his father exhibited low oxygen saturation measured transcutaneously by pulse oximetry, a finding that could not be confirmed by arterial blood gas analysis. Both patients exhibited slight hemolysis in their blood, and the boy had a microcytic anemia. There was no evidence of hypoxemia or methemoglobinemia. Despite the normal results from the arterial blood gas analysis, a right-to-left-shunt was assumed in the boy until a cardiology examination excluded this diagnosis. Sleep apnea syndrome was suspected in the father and treated with nocturnal positive pressure respiration based on the low oxygen saturation values obtained with pulse oximetry. Only after consultation with our laboratory was a hemoglobin variant suspected and investigated. METHODS We performed hemoglobin protein analysis by HPLC, electrophoretic separation, and spectrophotometry and DNA sequence analysis of the alpha-globin gene. RESULTS Both HPLC chromatographic separation and alkaline electrophoresis revealed a unique hemoglobin peak. In both patients, alpha-globin gene sequencing revealed a mutation resulting in a histidine-to-aspartatic acid substitution at position alpha87. The low oxygen saturation measurement by pulse oximetry was due to hemoglobin Bonn oxyhemoglobin having an absorption peak at 668 nm, near the 660 nm measured by pulse oximeters. CONCLUSION Hemoglobin Bonn is a novel hemoglobin variant of the proximal alpha-globin that results in falsely low oxygen saturation measurements with pulse oximetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 14-year-old boy with chronic cyanosis, mild anemia, and limited physical resistance to stress.

In April 1997, a then 4-year-old boy suddenly fell ill with fever, cough, fatigue, and poor physical resistance to stress. Marked cyanosis of the lips and the nail beds was noted. During his 3-week hospital stay, mycoplasmosis of the lung and a respiratory syncytial virus infection were diagnosed by the detection of high-titer Mycoplasma agglutinins in serum samples and positive test results fo...

متن کامل

Validation of Oxygen Saturation Monitoring In

www.ajcconline.org • BACKGROUND Pulse oximetry is commonly used to monitor oxygenation in neonates, but cannot detect variations in hemoglobin. Venous and arterial oxygen saturations are rarely monitored. Few data are available to validate measurements of oxygen saturation in neonates (venous, arterial, or pulse oximetric). • PURPOSE To validate oxygen saturation displayed on clinical monitors ...

متن کامل

Pulse oximetry during low perfusion caused by emerging pneumonia and sepsis in rabbits.

OBJECTIVE This study tested the effects of low perfusion caused by emerging sepsis on the reliability of a new pulse oximetry technology (Masimo SET; IVY 405T) compared with a standard pulse oximeter (Nellcor N-200). DESIGN Randomized trial. SETTING University animal research facility. SUBJECTS Twenty-six anesthetized, ventilated (Fio, 1.0), adult rabbits. INTERVENTIONS Pneumonia/sepsis...

متن کامل

Effect of Nail Polish on Pulse Oximetry Findings in Healthy Volunteers: A Randomized Clinical Trail

Background and Objectives: Pulse oximetry is the most common technique for monitoring hemoglobin oxygen saturation (SpO2). Different colors and brands of nail polish may cause disturbance in the reading and interpretation of oxygen saturation. The aim of this study was to determine the effect of different colors of nail polish on oxygen saturation measured by pulse oximeter. Methods: Thirty he...

متن کامل

Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.

Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2008