QRS complex widening as a predictor of appropriate implantable cardioverter-defibrillator (ICD) therapy and higher mortality risk in primary prevention ICD patients.

نویسندگان

  • Aleksander Maciąg
  • Andrzej Przybylski
  • Maciej Sterliński
  • Michał Lewandowski
  • Katarzyna Gepner
  • Ilona Kowalik
  • Paweł Derejko
  • Mariusz Pytkowski
  • Lukasz Szumowski
  • Hanna Szwed
چکیده

BACKGROUND AND AIM Effectiveness of implantable cardioverter-defibrillators (ICD) in patients with reduced left ventricular ejection fraction after myocardial infarction has been documented in large randomised trials. We analysed the predictive value of clinical factors at the time of implantation for adequate ICD interventions and mortality risk. METHODS We analysed 121 consecutive patients (15 women, 106 [88%] men; mean age 62 ± 10 years) with coronary artery disease in whom ICD was implanted for primary prevention between 2001 and 2007. Mean duration of follow-up was 876 ± 538 days. RESULTS Forty-four (36.4%) patients had adequate ICD interventions. In the Cox analysis, wider QRS complexes (hazard ration [HR] per each 10 ms increment: 1.13, confidence interval [CI] 1.039-1.229, p = 0.0045) and younger age at the time of ICD implantation (HR per each 10 year increment: 0.7, CI 0.5-0.9, p = 0.0081) were associated with a higher probability of adequate intervention. Wider QRS complexes were associated with a higher probability of electrical storm (HR 1.059, CI 1.014-1.045, p = 0.0002). During follow-up, 21 (17.4%) patients died. In the Cox analysis, wider QRS complexes (HR per each 10 ms increment: 1.123, CI 1.011-1.248, p = 0.0306 [in univariate analysis only]), older age at the time of implantation (HR per each 10 year increment: 1.7, CI 1.1-2.8, p = 0.0396) and higher NYHA class (HR 4.4, CI 1.7-11.5, p = 0.0022) were associated with increased mortality. Mortality was reduced by previous revascularisation (HR 0.3, CI 0.1-0.7, p = 0.006). CONCLUSIONS Patients with wider QRS complexes at the time of ICD implantation had a higher probability of adequate device intervention and mortality risk. QRS complex widening was also associated with a higher incidence of electrical storm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین عوامل مرتبط با دریافت شوک‎های به‌جا و نابه‌جای ICD در بیماران قلبی

 Background and Aim: The QRS duration is a strong predictor of mortality, particularly in heart failure patients. However, studies on the usefulness of QRS duration, as a predictor of ventricular arrhythmic events in ICD patients, have proved to be contradictory. Since in patients with implantable cardioverter defibrillator (ICD), all of the malignant ventricular arrhythmias are recorded and tr...

متن کامل

Predictors of appropriate therapy in patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death

The purpose of this study was to evaluate predictors of appropriate therapy in patients with implantable cardioverter-defibrillators (ICD) for primary prevention of sudden cardiac death. A retrospective cohort of 321 patients with systolic heart failure undergoing ICD placement for primary prevention of sudden cardiac death was queried with a mean follow-up period of 2.6 years. Appropriate ICD ...

متن کامل

Mortality Implications of Appropriate Implantable Cardioverter Defibrillator Therapy in Secondary Prevention Patients: Contrasting Mortality in Primary Prevention Patients From a Prospective Population‐Based Registry

BACKGROUND We sought to examine the mortality impact of appropriate implantable cardioverter defibrillator (ICD) therapy between patients who received ICD for primary versus secondary prevention purposes. METHODS AND RESULTS From a prospective, population-based registry, we identified 7020 patients who underwent de novo ICD implantation between February 2007 and May 2012 in Ontario, Canada. T...

متن کامل

Death Without Prior Appropriate Implantable Cardioverter-Defibrillator Therapy A Competing Risk Study

Background—Implantable cardioverter-defibrillators (ICDs) improve survival in selected patients with left ventricular systolic dysfunction in randomized trials. Competing death without prior appropriate ICD therapy might preclude benefit from ICD implantation in a less selected routine-care population. Methods and Results—We selected all patients with ischemic or dilated cardiomyopathy with an ...

متن کامل

Death Without Prior Appropriate Implantable Cardioverter-Defibrillator Therapy

Background—Implantable cardioverter-defibrillators (ICDs) improve survival in selected patients with left ventricular systolic dysfunction in randomized trials. Competing death without prior appropriate ICD therapy might preclude benefit from ICD implantation in a less selected routine-care population. Methods and Results—We selected all patients with ischemic or dilated cardiomyopathy with an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 70 4  شماره 

صفحات  -

تاریخ انتشار 2012