Airway narrowing measured by spirometry and impulse oscillometry following room temperature and cold temperature exercise.

نویسندگان

  • Tina M Evans
  • Kenneth W Rundell
  • Kenneth C Beck
  • Alan M Levine
  • Jennifer M Baumann
چکیده

STUDY OBJECTIVE The efficacy of using impulse oscillometry (IOS) as an indirect measure of airflow obstruction compared to spirometry after exercise challenges in the evaluation of exercise-induced bronchoconstriction (EIB) has not been fully appreciated. The objective was to compare airway responses following room temperature and cold temperature exercise challenges, and to compare whether IOS variables relate to spirometry variables. DESIGN Spirometry and IOS were performed at baseline and for 20 min after challenge at 5-min intervals. SETTING Two 6-min exercise challenges, inhaling either room temperature (22.0 degrees C) or cold temperature (- 1 degrees C) dry medical-grade bottled air. At least 48 h was observed between these randomly assigned challenges. PARTICIPANTS Twenty-two physically active individuals (12 women and 10 men) with probable EIB. INTERVENTIONS Subjects performed 6 min of stationary cycle ergometry while breathing either cold or room temperature medical-grade dry bottled air. Subjects were instructed to exercise at the highest intensity sustainable for the duration of the challenge. Heart rate and kilojoules of work performed were documented to verify exercise intensity. MEASUREMENTS AND RESULTS Strong correlations were observed within testing modalities for post-room temperature and post-cold temperature exercise spirometry and IOS values. Spirometry revealed no differences in postexercise peak falls in lung function between conditions; however, IOS identified significant differences in respiratory resistance (p < 0.05), with room temperature-inspired air being more potent than cold temperature-inspired air. CONCLUSIONS Correlations were found between spirometric and IOS measures of change in airway function for both exercise challenges, indicating close equivalency of the methods. The challenges appeared to elicit the EIB response by a similar mechanism of water loss, and cold temperature did not have an additive effect. IOS detected a difference in degree of response between the temperatures, whereas spirometry indicated no difference, suggesting that IOS is a more sensitive measure of change in airway function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exercise induced changes in spirometry and impulse oscillometry measurements in persistent allergic rhinitis.

The link between allergic rhinitis and asthma is well known. Bronchial hyperreactivity (BHR) may be present in rhinitis. The present study was aimed to compare airway responses in patients with rhinitis symptoms alone following exercise challenge, and to determine relationship of two different respiratory function tests.98 subjects with rhinitis were investigated by spirometry and impulse oscil...

متن کامل

Assessment of central airway obstruction using impulse oscillometry before and after interventional bronchoscopy.

BACKGROUND Spirometry is used to physiologically assess patients with central airway obstruction (CAO) before and after interventional bronchoscopy, but is not always feasible in these patients, does not localize the anatomic site of obstruction, and may not correlate with the patient's functional impairment. Impulse oscillometry may overcome these limitations. We assessed the correlations betw...

متن کامل

Advantage of impulse oscillometry over spirometry to diagnose chronic obstructive pulmonary disease and monitor pulmonary responses to bronchodilators: An observational study

OBJECTIVES This retrospective study was a comparative analysis of sensitivity of impulse oscillometry and spirometry techniques for use in a mixed chronic obstructive pulmonary disease group for assessing disease severity and inhalation therapy. METHODS A total of 30 patients with mild-to-moderate chronic obstructive pulmonary disease were monitored by impulse oscillometry, followed by spirom...

متن کامل

Impulse Oscillometry and Spirometry Small-Airway Parameters in Mild to Moderate Bronchiectasis.

BACKGROUND Both impulse oscillometry and spirometry can reflect small-airway disorders. The objective of this work was to investigate the diagnostic value of impulse oscillometry and spirometry small-airway parameters and their correlation with radiology, disease severity, and sputum bacteriology in mild to moderate bronchiectasis (bronchiectasis severity index <9) and to validate these finding...

متن کامل

Efficiency of cold passover and heated humidification under continuous positive airway pressure.

Cold passover and heated humidifiers are employed for the prevention of side-effects associated with continuous positive airway pressure (CPAP) treatment. However, to date, it has not been possible to separately measure the humidity of inspired and expired air. The aim of this study was to compare the relative humidity of the inspired air and the water loss during respiration between cold passo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 128 4  شماره 

صفحات  -