A study of the timing properties of position-sensitive avalanche photodiodes.

نویسندگان

  • Yibao Wu
  • Thomas S C Ng
  • Yongfeng Yang
  • Kanai Shah
  • Richard Farrell
  • Simon R Cherry
چکیده

In this paper, we study position-dependent timing shifts and timing resolution in position sensitive avalanche photodiodes (PSAPDs) and their effects on the coincidence window used in positron emission tomography (PET) systems using these devices. There is a delay in PSAPD signals that increases as the excitation position moves from the corner to the center of the device and the timing resolution concurrently worsens. The difference in timing between the center and the corner can be up to 30.7 ns for a 14 x 14 mm(2) area PSAPD. This means that a PSAPD-based PET system could require a very wide coincidence timing window (>60 ns) if this effect is not corrected, although the individual crystal pairs still have full-width half-maximum (FWHM) timing resolutions better than 7.4 ns. In addition to characterizing the timing properties of PSAPDs, two correction methods were developed and applied to data from a pair of PSAPD detectors. These two timing offset corrections reduced the timing shift of a crystal pair from 52.4 ns to 9.7 ns or 1.3 ns, improved the FWHM timing resolution of the detector pair from 24.6 ns to 9.5 ns or 6.0 ns and reduced the timing window (sufficient to cover at least twice the FWHM for all crystal pairs) from 65.1 ns to 22.0 ns or 15.2 ns, respectively. A two-step timing alignment method is proposed for a PET system consisting of multiple PSAPDs. Lastly, the effect of PSAPD size on the timing performance was also evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Position-Sensitive Avalanche Photodiodes for Gamma-Ray Imaging

In this paper, we report on the investigation of silicon avalanche photodiodes (APDs) for high-energy photon imaging applications. This includes a new APD design that provides X-ray and -ray imaging with significant reduction in electronic readout requirements. This new APD design, referred to as position-sensitive avalanche photodiode (PSAPD), involves charge sharing amongst the electrodes tha...

متن کامل

Full-band Monte Carlo simulation of high-energy carrier transport in single photon avalanche diodes: Computation of breakdown probability, time to avalanche breakdown, and jitter

Related Articles Ultra-low noise single-photon detector based on Si avalanche photodiode Rev. Sci. Instrum. 82, 093110 (2011) GaN/SiC avalanche photodiodes Appl. Phys. Lett. 99, 131110 (2011) Influence of the metallic contact in extreme-ultraviolet and soft x-ray diamond based Schottky photodiodes J. Appl. Phys. 110, 054513 (2011) Organic position sensitive photodetectors based on lateral donor...

متن کامل

Monte Carlo Simulation of Multiplication Factor in PIN In0.52Al0.48As Avalanche Photodiodes

In this paper, we calculate electron and hole impactionization coefficients in In0.52Al0.48As using a Monte Carlo modelwhich has two valleys and two bands for electrons and holesrespectively. Also, we calculate multiplication factor for electronand hole initiated multiplication regimes and breakdown voltagein In0.52Al0.48As PIN avalanche photodiodes. To validate themodel, we compare our simulat...

متن کامل

Performance of InGaAs/InP Avalanche Photodiodes as Gated-Mode Photon Counters.

We investigate the performance of separate absorption multiplication InGaAs/InP avalanche photodiodes as single-photon detectors for 1.3- and 1.55-mum wavelengths. First we study afterpulses and choose experimental conditions to limit this effect. Then we compare the InGaAs/InP detector with a germanium avalanche photodiode; the former shows a lower dark-count rate. The effect of operating temp...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 17  شماره 

صفحات  -

تاریخ انتشار 2009