The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology.
نویسندگان
چکیده
During the First International EEG Congress, London in 1947, it was recommended that Dr. Herbert H. Jasper study methods to standardize the placement of electrodes used in EEG (Jasper 1958). A report with recommendations was to be presented to the Second International Congress in Paris in 1949. The electrode placement systems in use at various centers were found to be similar, with only minor differences, although their designations, letters and numbers were entirely different. Dr. Jasper established some guidelines which would be established in recommending a speci®c system to the federation and these are listed below.
منابع مشابه
Visual information processing in dyslexic children.
OBJECTIVE Several studies presented evidence for magnocellular deficits in dyslexics both in behavioural as well as in electrophysiological data of local electrode sites. We investigated two well-known paradigms (motion-onset and random-dot-kinematogram) with regard to global electrophysiological parameters. METHODS Twenty-one-channel event-related potentials (ERPs) of 16 dyslectic and 15 con...
متن کاملReference values in concentric needle electrode studies.
A recommendation of considerable concern is that different cutoff limits be used ‘‘depending on the clinical purpose’’. The electromyographer must report the results objectively and distinguish clearly between the results of electrophysiologic testing and conclusions based on other factors. There should only be one cutoff value, but the ultimate interpretation should take into account clinical ...
متن کاملModulation of brain criticality via suppression of EEG long-range temporal correlations (LRTCs) in a closed-loop neurofeedback stimulation.
متن کامل
Electroencephalographic recording during transcranial magnetic stimulation in humans and animals.
OBJECTIVE We report on the development of an EEG recording system, comprised of electrodes and amplifiers that are compatible with TMS (single and rapid-rate) in both human and animal studies. METHODS We assembled a versatile multi-channel EEG recording system consisting of: (1) two types of electrodes that are safe during TMS or rTMS. (2) Low slew-rate EEG amplifiers that recover within a fe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Electroencephalography and clinical neurophysiology. Supplement
دوره 52 شماره
صفحات -
تاریخ انتشار 1999