Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements.

نویسندگان

  • B Rubin
  • J L Topper
  • C C Farnell
  • A P Yalin
چکیده

We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 degrees-70 degrees from normal. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV) and a two-grid ion optics is used for higher energies (up to 750 eV). A complementary weight loss approach is also used to measure total sputter yields. Validation experiments are presented that confirm high sensitivity and accuracy of sputter yield measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total and Differential Sputter Yields of Boron Nitride Measured by Quartz Crystal Microbalance

We present differential sputter yield measurements of boron nitride due to bombardment by xenon ions. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV). A quartz crystal microbalance (QCM) is used to measure differential sputter yield profiles of condensable components from which total sputter yields can also be determined. We report total and differ...

متن کامل

Differential Sputter Yields Of Boron Nitride, Quartz, and Kapton Due to Low Energy Xe Bombardment

In this contribution we present results of differential sputter yield measurements of boron nitride, quartz, and kapton due to bombardment by xenon ions. The measurements are made using a sputtering diagnostic based on a quartz crystal microbalance (QCM). The QCM measurement allows full angular resolution, i.e. differential sputtering yield measurements are measured as a function of both polar ...

متن کامل

Sputtering yield measurements at glancing incidence using a quartz crystal microbalance

Low energy sputtering yields at grazing incidence have been investigated experimentally using a quartz crystal microbalance QCM technique. This method involved precoating the QCM with a thin film of the desired target material and relating the resonance frequency shift directly to mass loss during ion bombardment. A highly focused, low divergence ion beam provided a well defined incidence angle...

متن کامل

Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies

We developed an impedance quartz crystal microbalance (QCM) approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer. This impedance QCM measures frequency shifts and resistance changes of sensing quartz crystals very stable, accurately, and calibrated, thus yielding quantitative information on mass chang...

متن کامل

C60 molecular depth profiling of a model polymer

The bombardment of a 26 nm poly(methyl methacrylate) (PMMA) film has been studied as a model for depth profiling of polymeric samples using a newly developed C60 þ ion source. Experiments were conducted on a ToF-SIMS instrument equipped with C60 þand Gaþ ion sources. A focused dc C60 þ ion beam was used to etch through the polymer sample at specified time intervals. Subsequent spectra were reco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 10  شماره 

صفحات  -

تاریخ انتشار 2009