A method exploiting direct communication between phasor measurement units for power system wide-area protection and control algorithms

نویسندگان

  • Muhammad Shoaib Almas
  • Luigi Vanfretti
چکیده

Synchrophasor measurements from Phasor Measurement Units (PMUs) are the primary sensors used to deploy Wide-Area Monitoring, Protection and Control (WAMPAC) systems. PMUs stream out synchrophasor measurements through the IEEE C37.118.2 protocol using TCP/IP or UDP/IP. The proposed method establishes a direct communication between two PMUs, thus eliminating the requirement of an intermediate phasor data concentrator, data mediator and/or protocol parser and thereby ensuring minimum communication latency without considering communication link delays. This method allows utilizing synchrophasor measurements internally in a PMU to deploy custom protection and control algorithms. These algorithms are deployed using protection logic equations which are supported by all the PMU vendors. Moreover, this method reduces overall equipment cost as the algorithms execute internally in a PMU and therefore does not require any additional controller for their deployment. The proposed method can be utilized for fast prototyping of wide-area measurements based protection and control applications. The proposed method is tested by coupling commercial PMUs as Hardware-in-the-Loop (HIL) with Opal-RT's eMEGAsim Real-Time Simulator (RTS). As illustrative example, anti-islanding protection application is deployed using proposed method and its performance is assessed. The essential points in the method are: •Bypassing intermediate phasor data concentrator or protocol parsers as the synchrophasors are communicated directly between the PMUs (minimizes communication delays).•Wide Area Protection and Control Algorithm is deployed using logic equations in the client PMU, therefore eliminating the requirement for an external hardware controller (cost curtailment)•Effortless means to exploit PMU measurements in an environment familiar to protection engineers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements

In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...

متن کامل

Improving Monitoring, Control and Protection of Power Grid Using Wide Area Synchro-Phasor Measurements

When disturbances occur in power grid, monitoring, control and protection systems are required to stop the grid degradation, restore it to a normal state, and hence minimize their effects. However, in wide area power grid resulting from large extension and interconnection with neighbor grids, classical systems based on local independent measurements and decisions are not able to consider the ov...

متن کامل

Optimal Placement of Phasor Measurement Units in Khorasan Network Using a Hybrid Intelligent Technique

In this paper, an efficient and comprehensive hybrid intelligent technique for the optimal placement of phasor measurement units (PMUs) is proposed to minimize the number of PMU installation subjected to full network observability. Three main purposes of PMUs output synchronous measurements are monitoring, control, and protection of power system. We have combined Binary Imperialistic Competitio...

متن کامل

Reliability Assessment of Power System Backup Protection in Smart Grid Control Center Using Phasor Measurement Units (PMU)

Catastrophic failures in power grid due to maloperation of traditional backup protection system (e.g. third zone of distance relays) was one of the main causes of many cascade trips. This paper assess a new wide-area backup protection system (WABPS) based on phasor measurement units (PMU), to improve third zone of distance relays to avoid its mal-operation. Based on this assessment, phasor meas...

متن کامل

Presenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units

In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017