A novel method to assess primary stability of press-fit acetabular cups.

نویسندگان

  • Emilie A Crosnier
  • Patrick S Keogh
  • Anthony W Miles
چکیده

Initial stability is an essential prerequisite to achieve osseointegration of press-fit acetabular cups in total hip replacements. Most in vitro methods that assess cup stability do not reproduce physiological loading conditions and use simplified acetabular models with a spherical cavity. The aim of this study was to investigate the effect of bone density and acetabular geometry on cup stability using a novel method for measuring acetabular cup micromotion. A press-fit cup was inserted into Sawbones(®) foam blocks having different densities to simulate normal and osteoporotic bone variations and different acetabular geometries. The stability of the cup was assessed in two ways: (a) measurement of micromotion of the cup in 6 degrees of freedom under physiological loading and (b) uniaxial push-out tests. The results indicate that changes in bone substrate density and acetabular geometry affect the stability of press-fit acetabular cups. They also suggest that cups implanted into weaker, for example, osteoporotic, bone are subjected to higher levels of micromotion and are therefore more prone to loosening. The decrease in stability of the cup in the physiological model suggests that using simplified spherical cavities to model the acetabulum over-estimates the initial stability of press-fit cups. This novel testing method should provide the basis for a more representative protocol for future pre-clinical evaluation of new acetabular cup designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact sensitivity analysis of FE model of the pelvis with press-fit acetabular prosthesis

Introduction Lack of primary stability has been regarded as a major cause for implant loosening in total hip arthroplasty. For a cementless press-fit acetabular cup, primary stability is achieved by inserting an oversized component into an under-reamed acetabulum. Two features that result from the press-fitting process are – 1) pre-stress due to the difference in the radii of the cup and the re...

متن کامل

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...

متن کامل

Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

BACKGROUND Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. METHODS The maximum tilting moment fo...

متن کامل

Comparative in vitro assessment of the primary stability of cementless press-fit acetabular cups.

Long-term stable osseointegration of porous-coated acetabular cups depends on bony ingrowth within their porous surface. For ingrowth to take place, one must ensure rigid initial fixation of the implant, by means of screws or by impaction or using a threaded ring. Primary stability is a prerequisite for long term stability through bony ingrowth. We tested several cups commonly used in our depar...

متن کامل

Experimental analysis of insertion torques and forces of threaded and press-fit acetabular cups by means of ex vivo and in vivo measurements.

PURPOSE In THA a sufficient primary implant stability is the precondition for successful secondary stability. Industrial foams of different densities have been used for primary stability investigations. The aim of this study was to analyse and compare the insertion behaviour of threaded and press-fit cups in vivo and ex vivo using bone substitutes with various densities. METHODS Two threaded ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 228 11  شماره 

صفحات  -

تاریخ انتشار 2014