Comparison of tumor and normal tissue oxygen tension measurements using OxyLite or microelectrodes in rodents.

نویسندگان

  • R D Braun
  • J L Lanzen
  • S A Snyder
  • M W Dewhirst
چکیده

In this study we compare oxygen tension (PO2) histograms measured with O2 microelectrodes and a new optical PO2 measurement device, the OxyLite, in normal tissues (mouse spleen and thymus) and in tumors (R3230Ac in rats) (n = 5-6). The transient response to glucose infusion or 100% O2 breathing (hyperoxia) was also measured in tumors. PO2 histograms of spleen and thymus with the two devices were not different. The OxyLite tumor PO2 histogram, however, was left-shifted compared with the microelectrode (median PO2 1.0 vs. 4.0 mmHg, P = 0.016). Both probes responded to acute hyperglycemia with a mean increase of 3-6 mmHg, but the microelectrode change was not significant. The OxyLite consistently recorded large PO2 increases (approximately 28 mmHg) with hyperoxia, whereas the microelectrode response was variable. The OxyLite averages PO2 over an area that contains interstitial and vascular components, whereas the microelectrode measures a more local PO2. This study demonstrates the importance of considering the features of the measurement device when studying tissues with heterogeneous PO2 distributions (e.g., tumors).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electron paramagnetic resonance oxygen images correlate spatially and quantitatively with Oxylite oxygen measurements.

Tumor oxygenation predicts cancer therapy response and malignant phenotype. This has spawned a number of oxymetries. Comparison of different oxymetries is crucial for the validation and understanding of these techniques. Electron paramagnetic resonance (EPR) imaging is a novel technique for providing quantitative high-resolution images of tumor and tissue oxygenation. This work compares sequenc...

متن کامل

Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: a comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry.

BACKGROUND AND PURPOSE (18)F-FAZA is a nitroimidazole PET tracer that can provide images of tumor hypoxia. However, it cannot provide absolute pO(2) values. To qualify (18)F-FAZA PET, we compared PET images to pO(2) measured by OxyLite, EPR oximetry and (19)F-MRI. MATERIALS AND METHODS Male WAG/Rij rats grafted with rhabdomyosarcoma were used. Tumor oxygenation was modified by gas breathing (...

متن کامل

Hyperglycemia impairs retinal oxygen autoregulation in normal and diabetic dogs.

Preretinal oxygen tensions were measured continuously using microelectrodes in four normal dogs and four dogs made diabetic with alloxan. The latter were kept under poor control for 8 months. Glucose administered intravenously in 30 to 90 sec to all the dogs when they were normoglycemic caused an immediate increase in preretinal oxygen tension lasting approximately 10 min. When the dogs were gi...

متن کامل

Retinal tissue oxygen tension in normoxic cats under enflurane anesthesia.

PURPOSE General anesthesia reduces systemic blood pressure and, thus, ocular perfusion pressure (at constant intraocular pressure). Whether this reduction in ocular perfusion pressure produces retinal hypoxia is unknown. To answer this question, the authors measured inner retinal oxygen tension in cats under general enflurane anesthesia at three clinically relevant levels of anesthesia under no...

متن کامل

Evaluation of CDH1&RUNX3 Expression in Cancerous and Normal Tissue of Patients With Gastric Cancer

Introduction: Gastric cancer is a multifactorial disease and the fourth most common cancer in the world and the second cause of death from cancer. This study was designed and performed to investigate CDH1 and RUNX3 genes expression in healthy and tumor marginal tissue of people with gastric cancer. Methods: In this case-control study, 64 samples including 32 samples of gastric tumor tissue a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 280 6  شماره 

صفحات  -

تاریخ انتشار 2001