Constrained independent component analysis approach to nonobtrusive pulse rate measurements.
نویسندگان
چکیده
Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.
منابع مشابه
Health Monitoring for Elderly: An Application Using Case-Based Reasoning and Cluster Analysis
This paper presents a framework to process and analyze data from a pulse oximeter which remotely measures pulse rate and blood oxygen saturation from a set of individuals. Using case-based reasoning (CBR) as the backbone to the framework, records are analyzed and categorized according to their similarity. Record collection has been performed using a personalized health profiling approach in whi...
متن کاملEfficiency Measurement of Clinical Units Using Integrated Independent Component Analysis-DEA Model under Fuzzy Conditions
Background and Objectives: Evaluating the performance of clinical units is critical for effective management of health settings. Certain assessment of clinical variables for performance analysis is not always possible, calling for use of uncertainty theory. This study aimed to develop and evaluate an integrated independent component analysis-fuzzy-data envelopment analysis approach to accurate ...
متن کاملA Case-Based Patient Identification System using Pulse Oximeter and a Personalized Health Profile
This paper proposes a case-based system framework in order to identify patient using their health parameters taken with physiological sensors. It combines a personalized health profiling protocol with a Case-Based Reasoning (CBR) approach. The personalized health profiling helps to determine a number of individual parameters which are important inputs for a clinician to make the final diagnosis...
متن کاملSecond Law Based Analysis of Fluid Flow in the Regenerator of Pulse Tube Refrigerators
As a necessary component, regenerator plays an important role in the refrigeration performance of the pulse tube refrigerator. The objective of this research is to investigate the flow characteristics in a porous regenerator of the pulse tube refrigerators, subjected to oscillating flow. The hydrodynamic and thermal behavior of the regenerator is investigated by considering porous media approac...
متن کاملNon-contact, automated cardiac pulse measurements using video imaging and blind source separation.
Remote measurements of the cardiac pulse can provide comfortable physiological assessment without electrodes. However, attempts so far are non-automated, susceptible to motion artifacts and typically expensive. In this paper, we introduce a new methodology that overcomes these problems. This novel approach can be applied to color video recordings of the human face and is based on automatic face...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2012