Is there a preferred IMRT technique for left‐breast irradiation?

نویسندگان

  • Marloes Jeulink
  • Max Dahele
  • Philip Meijnen
  • Ben J. Slotman
  • Wilko F.A.R. Verbakel
چکیده

Not all clinics have breath-hold radiotherapy available for left-breast irradiation. However intensity-modulated radiotherapy (IMRT) has also been advocated as a means of lowering heart doses. There is currently no large-scale, long-term follow-up data after breast IMRT and, since dose distributions may differ from classic tangent-based radiotherapy, caution is needed to avoid unexpected worsening of the late toxicity profile. We compared four IMRT techniques for free-breathing left-breast irradiation. Consistent with the aforementioned concerns, our goal in planning was to prioritize organ at risk (OAR) sparing in a way that mimicked tangent-based radiotherapy. Ten simultaneous integrated boost treatment plans (PTVelective = 15 × 2.67 Gy; PTVboost = 15 × 3.35 Gy) were created using 1) hybrid-IMRT (H-IMRT), 2) full IMRT (F-IMRT), and 3) volumetric-modulated arc therapy with two partial arcs (2ARC) and 4) six partial arcs (6ARC). Reduction in OAR mean and low dose was prioritized. End-points included OAR sparing (e.g., heart, left anterior descending artery [LAD+3 mm], lungs, and contralateral breast) and PTV coverage/dose homogeneity. Under these conditions we found the following: 1) H-IMRT provided the best mean and low dose OAR sparing, PTVelective coverage (mean V95% = 98%), PTVboost coverage (V95% = 98%), and PTV homogeneity. However, it delivered most intermediate-high dose to the heart, LAD+3 mm and ipsilateral lung; 2) 6ARC had the best intermediate-high dose sparing, followed by F-IMRT, but this was at the expense of more dose in the contralateral lung and breast and worse PTV coverage (PTVelective mean V95% = 96%/97% and PTVboost mean V95% = 91%/96% for 6ARC/F-IMRT). When trying to spare mean and low dose to OARs, the preferred IMRT technique for left-breast irradiation without breath-hold was H-IMRT. This is currently the standard solution in our institution for left-breast radiotherapy under free-breathing and breath-hold conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Intensity Modulated Radiation Therapy (IMRT) of the Breast and Lung

When Policy Topic is covered Intensity-modulated radiation therapy (IMRT) may be considered medically necessary as a technique to deliver whole breast irradiation in patients receiving treatment for left-sided breast cancer after breast-conserving surgery when all the following conditions have been met:  Significant cardiac radiation exposure cannot be avoided using alternative radiation techn...

متن کامل

Dosimetric comparison of left-sided whole breast irradiation with 3D-CRT, IP-IMRT and hybrid IMRT.

The aim of this study was to compare the dosimetric characteristics of left-sided whole breast irradiation among 3-dimensional conformal radiotherapy (3D-CRT), 4-field inverse-planned intensity-modulated radiotherapy (IP-IMRT) and hybrid IMRT technique (combining 3D-CRT beams and IP-IMRT beams) with respect to target coverage and irradiation of organs at risk. The 3 different planning technique...

متن کامل

Early experience of tomotherapy-based intensity-modulated radiotherapy for breast cancer treatment.

AIMS New technology - specifically intensity-modulated radiotherapy (IMRT) - is now being applied to breast radiotherapy and a recent dosimetric analysis confirmed the advantages of IMRT over 'wedge-only' plans. Such application to everyday practice raises new issues and here we present the early experience of IMRT-based breast irradiation in a single centre. MATERIALS AND METHODS We present ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015