A precision cryostat design for manual and semi-automated cryo-plunge instruments

نویسندگان

  • Christopher J. Russo
  • Steve Scotcher
  • Martin Kyte
چکیده

Here we describe a bench-top cryostat system to control the temperature of liquid ethane in a cryo-plunge apparatus designed for biological specimen preparation for electron cryomicroscopy. It comprises a foam insulated Dewar containing a copper cryostat cup, whose temperature is controlled via an active feedback system to within 0.1 K. The device can easily be incorporated into existing manual and semi-automatic cryo-plunge instruments that are not equipped with cryogenic temperature control. Over the course of normal use, we find that using a cryostat is convenient, fast, and does not require special mixtures of cryogens like ethane/propane. This simple cryostat improves the reliability and reproducibility of biological specimen preparation for electron cryomicroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative precision analysis of Precision-controls on automated chemistry analyzers

Background: Automated diagnostic equipments took over manual testing in last three decades, that allowed enhanced reproducibility, precision and accurateness of results; in addition to 24/7 availability of major lab testing profiles. Aim: In this regard, present study described comparative equipments’ precision assessment of conventional chemistry analyzer, Hirachi 912 with Cobas c501 on parame...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Cryogenic probe station for on-wafer characterization of electrical devices.

A probe station, suitable for the electrical characterization of integrated circuits at cryogenic temperatures is presented. The unique design incorporates all moving components inside the cryostat at room temperature, greatly simplifying the design and allowing automated step and repeat testing. The system can characterize wafers up to 100 mm in diameter, at temperatures <20 K. It is capable o...

متن کامل

Automatic post-picking using MAPPOS improves particle image detection from Cryo-EM micrographs

Cryo-electron microscopy (cryo-EM) studies using single particle reconstruction are extensively used to reveal structural information on macromolecular complexes. Aiming at the highest achievable resolution, state of the art electron microscopes automatically acquire thousands of high-quality micrographs. Particles are detected on and boxed out from each micrograph using fully- or semi-automate...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2016