Morphology variability of radial pulse wave during exercise.

نویسندگان

  • Lisheng Xu
  • Yang Yao
  • Hao Wang
  • Dianning He
  • Lu Wang
  • Yongsheng Jiang
چکیده

Pulse wave contains much information on a cardiovascular system. Pulse wave variability during exercise is of great significance as it reflects more information combining with pulse wave under stationary state. This paper studied the morphology variability of radial pulse wave during exercise. Radial pulse waves were collected from 30 subjects with two pressure pulse sensors worn at the wrists of the right and left hands, respectively. Electrocardiography (ECG) was also detected synchronously. After data preprocessing and feature point extraction, the variability of several parameters of pulse wave and ECG were analyzed. It is notable that pulse rate (PR) and heart rate (HR) change synchronously. During the exercise period, both systolic phase and diastolic phase of a radial pulse shorten but the latter is more obvious. The amplitude of the dicrotic notch decreases and even turns negative. Aligning the radial pulse waveforms together, the radial pulse waveforms prior to, during and after exercise coincide with each other except for some details like the tidal wave which fades away during exercise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exercise reduces arterial pressure augmentation through vasodilation of muscular arteries in humans.

Exercise markedly influences pulse wave morphology, but the mechanism is unknown. We investigated whether effects of exercise on the arterial pulse result from alterations in stroke volume or pulse wave velocity (PWV)/large artery stiffness or reduction of pressure wave reflection. Healthy subjects (n = 25) performed bicycle ergometry. with workload increasing from 25 to 150 W for 12 min. Digit...

متن کامل

The differences in waveform between photoplethysmography pulse wave and radial pulse wave in movement station.

OBJECTIVE There are many similarities between the photoplethysmography(PPG) pulse wave and the radial pulse when a body is in a stationary state, but the difference between them under conditions of movement is not yet clear. Finding these differences may help further understanding of the cardiovascular system. METHODS PPG and radial pulse wave were recorded simultaneously while subjects were ...

متن کامل

Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man.

Central (aortic or subclavian), brachial, radial and femoral pressure pulses were recorded simultaneously in 12 healthy subjects during conditions of rest, exercise and 70 degree head-up tilt. Peripheral systolic pressure at rest uniformly exceeded the central systolic pressure generated by the same heartbeat. The average radial pulse pressure was 146, 146 and 165 per cent of central pulse pres...

متن کامل

Mechanism of a hypertensive response to exercise.

Mottram et al. (1) recently reported in the Journal new and unexpected findings: that a hypertensive response to exercise (systolic blood pressure 210 mm Hg in males and 190 mm Hg in females) in normotensive and hypertensive subjects is associated with subtle defects in systolic left ventricular (LV) function. A number of possible mechanisms were proposed. Another explanation, not canvassed, re...

متن کامل

An Inexpensive Arterial Pressure Wave Sensor and its application in different physiological condition

Arterial Blood Pressure wave monitoring is considered to be important in assessment of cardiovascular system. We developed a novel pulse wave detection system using low frequency specific piezoelectric material as pressure wave sensor. The transducer detects the periodic change in the arterial wall diameter produced by pressure wave and the amplified signal after integration represents the pres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2014