Note: atmospheric point discharge current measurements using a temperature-compensated logarithmic current amplifier.

نویسندگان

  • G J Marlton
  • R G Harrison
  • K A Nicoll
چکیده

Measurements of atmospheric corona currents have been made for over 100 years to indicate the atmospheric electric field. Corona currents vary substantially, in polarity and in magnitude. The instrument described here uses a sharp point sensor connected to a temperature compensated bi-polar logarithmic current amplifier. Calibrations over a range of currents from ±10 fA to ±3 μA and across ±20 °C show it has an excellent logarithmic response over six orders of magnitude from 1 pA to 1 μA in both polarities for the range of atmospheric temperatures likely to be encountered in the southern UK. Comparison with atmospheric electric field measurements during disturbed weather confirms that bipolar electric fields induce corona currents of corresponding sign, with magnitudes ~0.5 μA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current-input current-output CMOS logarithmic amplifier based on translinear Ohm’s law

State-of-the-art logarithmic amplifiers use a transimpedance technique based on the exponential dependence between input current and output voltage as exhibited by p-n junction diodes, bipolar transistors and MOS transistors in the subthreshold region. Presented is a CMOS current-input current-output logarithmic amplifier based on a translinear Ohm’s law principle which involves a floating volt...

متن کامل

Field Measurements of Velocity and Physical Parameters of Seawater and Numerical Modeling of Brine Discharge from the Desalination Plant in the Southeastern Coast of Kish Island-Iran

Abstract Temperature, salinity, water-level and current speed around brine outflow of desalination site in the Southeastern Coast of Kish Island is investigated. The dominant current is east-west tidal current with a weak residual current which affects current field partially southward. The brine discharge driven hypersaline pollution dispersion is simulated applying MIKE 21, considering thr...

متن کامل

A 39 dB DR CMOS Log-Amp RF Power Detector with ± 1.1 dB Temperature Drift from -40 to 85°C

This paper presents a temperature compensated logarithmic amplifier (log-amp) RF power detector implemented in CMOS 0.18μm technology. The input power can range from -50 to +10 dBm for RF signals ranging from 100 MHz to 1.5 GHz. This design attains a typical DR of 39 dB for a ±1 dB logconformance error (LCE). Up to 900 MHz the temperature drift is never larger than ±1.1 dB for all 24 measured s...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

Logarithmic current electrometer using light emitting diodes

The limit of low current measurement using logarithmic current to voltage converter is improved by 6–7 orders of magnitude with the use of diodes of large band gap as compared with silicon diodes. Low cost commercially available light emitting diodes (LEDs) have been used for this purpose. A theoretical study and experimental measurement of device constant and reverse saturation currents of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 6  شماره 

صفحات  -

تاریخ انتشار 2013