Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes.

نویسندگان

  • Richard M Bergenstal
  • William V Tamborlane
  • Andrew Ahmann
  • John B Buse
  • George Dailey
  • Stephen N Davis
  • Carol Joyce
  • Tim Peoples
  • Bruce A Perkins
  • John B Welsh
  • Steven M Willi
  • Michael A Wood
چکیده

BACKGROUND Recently developed technologies for the treatment of type 1 diabetes mellitus include a variety of pumps and pumps with glucose sensors. METHODS In this 1-year, multicenter, randomized, controlled trial, we compared the efficacy of sensor-augmented pump therapy (pump therapy) with that of a regimen of multiple daily insulin injections (injection therapy) in 485 patients (329 adults and 156 children) with inadequately controlled type 1 diabetes. Patients received recombinant insulin analogues and were supervised by expert clinical teams. The primary end point was the change from the baseline glycated hemoglobin level. RESULTS At 1 year, the baseline mean glycated hemoglobin level (8.3% in the two study groups) had decreased to 7.5% in the pump-therapy group, as compared with 8.1% in the injection-therapy group (P<0.001). The proportion of patients who reached the glycated hemoglobin target (<7%) was greater in the pump-therapy group than in the injection-therapy group. The rate of severe hypoglycemia in the pump-therapy group (13.31 cases per 100 person-years) did not differ significantly from that in the injection-therapy group (13.48 per 100 person-years, P=0.58). There was no significant weight gain in either group. CONCLUSIONS In both adults and children with inadequately controlled type 1 diabetes, sensor-augmented pump therapy resulted in significant improvement in glycated hemoglobin levels, as compared with injection therapy. A significantly greater proportion of both adults and children in the pump-therapy group than in the injection-therapy group reached the target glycated hemoglobin level. (Funded by Medtronic and others; ClinicalTrials.gov number, NCT00417989.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-Effectiveness Analysis of Sensor-Augmented Insulin Pump Therapy with Automated Insulin Suspension Versus Standard Insulin Pump Therapy in Patients with Type 1 Diabetes in Sweden

INTRODUCTION In Sweden an estimated 10,000 people with type 1 diabetes use continuous subcutaneous insulin infusion (CSII). Sensor-augmented pump therapy (SAP) is associated with higher acquisition costs but provides additional clinical benefits (e.g. reduced rate of hypoglycemic events) over and above that of CSII alone. The aim of the analysis was to assess the cost-effectiveness of SAP with ...

متن کامل

Comparative study on treatment satisfaction and health perception in children and adolescents with type 1 diabetes mellitus on multiple daily injection of insulin, insulin pump and sensor-augmented pump therapy

OBJECTIVES Diabetes management imposes considerable demands on patients. Treatment method used has an impact on treatment satisfaction. We aim to examine the relationship between treatment satisfaction and health perception with the method used for treatment of type 1 diabetes mellitus in children and adolescents. SUBJECTS AND METHOD We have interviewed patients with type 1 diabetes mellitus ...

متن کامل

Assessing the effectiveness of 3 months day and night home closed-loop insulin delivery in adults with suboptimally controlled type 1 diabetes: a randomised crossover study protocol

INTRODUCTION Despite therapeutic advances, many people with type 1 diabetes are still unable to achieve optimal glycaemic control, limited by the occurrence of hypoglycaemia. The objective of the present study is to determine the effectiveness of day and night home closed-loop over the medium term compared with sensor-augmented pump therapy in adults with type 1 diabetes and suboptimal glycaemi...

متن کامل

Faster insulin action is associated with improved glycaemic outcomes during closed‐loop insulin delivery and sensor‐augmented pump therapy in adults with type 1 diabetes

We aimed to evaluate the relationship between insulin pharmacodynamics and glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy. We retrospectively analysed data from a multicentre randomized control trial involving 32 adults with type 1 diabetes receiving day-and-night closed-loop insulin delivery and sensor-augmented pump therapy over 12 weeks. We estimated...

متن کامل

Day-and-Night Hybrid Closed-Loop Insulin Delivery in Adolescents With Type 1 Diabetes: A Free-Living, Randomized Clinical Trial

OBJECTIVE To evaluate feasibility, safety, and efficacy of day-and-night hybrid closed-loop insulin delivery in adolescents with type 1 diabetes under free-living conditions without remote monitoring or supervision. RESEARCH DESIGN AND METHODS In an open-label, randomized, free-living, crossover study design, 12 adolescents receiving insulin pump therapy (mean [±SD] age 15.4 ± 2.6 years; HbA1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 363 4  شماره 

صفحات  -

تاریخ انتشار 2010