Energy expenditure estimate by heart-rate monitor and a portable electromagnetic coils system.

نویسندگان

  • Steven Gastinger
  • Guillaume Nicolas
  • Anthony Sorel
  • Hamid Sefati
  • Jacques Prioux
چکیده

The aim of this article was to compare 2 portable devices (a heart-rate monitor and an electromagnetic-coil system) that evaluate 2 different physiological parameters--heart rate (HR) and ventilation (VE)--with the objective of estimating energy expenditure (EE). The authors set out to prove that VE is a more pertinent setting than HR to estimate EE during light to moderate activities (sitting and standing at rest and walking at 4, 5, and 6 km/hr). Eleven healthy men were recruited to take part in this study (27.6 ± 5.4 yr, 73.7 ± 9.7 kg). The authors determined the relationships between HR and EE and between VE and EE during light to moderate activities. They compared EE measured by indirect calorimetry (EEREF) with EE estimated by HR monitor (EEHR) and EE estimated by electromagnetic coils (EEMAG) in upright sitting and standing positions and during walking exercises. They compared EEREF with EEHR and EEMAG. The results showed no significant difference between the values of EEREF and EEMAG. However, they showed several significant differences between the values of EEREF and EEHR (for standing at rest and walking at 5 and 6 km/hr). These results showed that the electromagnetic-coil system seems to be more accurate than the HR monitor to estimate EE at rest and during exercise. Taking into consideration these results, it would be interesting to associate the parameters VE and HR to estimate EE. Furthermore, a new version of the electromagnetic-coil device was recently developed and provides the possibility to perform measurement under daily life conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart rate as a predictor of energy expenditure in people with spinal cord injury.

This study evaluated the accuracy of heart rate calibrated from a maximum exercise test for predicting energy expenditure during five activities of daily living (ADL) in participants with spinal cord injury (SCI). Thirteen individuals with SCI underwent maximum exercise testing, followed by portable heart rate and metabolic testing during five ADL. A regression equation was developed from heart...

متن کامل

تاثیر ارتز میلواکی بر شاخص‌های مصرف انرژی نوجوانان پسر مبتلا به کایفوز متحرک ناحیه توراسیک

    Background & Aim: Apart from poor cosmetic appearance, the most important potential consequence of spinal deformities is cardiorespiratory function. However, one of the reasons that patients discontinue wearing orthosis seems to be an increase in energy expenditure during activity apart from its cosmetic problem. The purpose of this study was to assess the effect of Milwaukee brace on energ...

متن کامل

Validation of the Actiheart Monitor for the Measurement of Physical Activity

Int J Exerc Sci 2(1) : 60-71, 2009. The Actiheart monitor uniquely allows simultaneous measurement of heart rate and movement counts. The purpose of this study was to establish validity evidence for the Actiheart monitor under laboratory and free-living conditions. A total of 34 college students (17 males and 17 females, age = 21.8 ± 3.6 years) participated in the study. In the laboratory envir...

متن کامل

The finite element analysis of the linear hybrid reluctance motor for the electromagnetic launch system

The Electromagnetic Aircraft Launch System (EMALS) is being developed utilizing electrical and electronic technologies. EMALS is emerging in order to replace the existing steam catapult on naval carriers. Recently, the double-sided linear launcher has drawn increasing attention of researchers. This paper presents the design and analysis of the Linear Hybrid Reluctance Motor (LHRM). This new mot...

متن کامل

Validation of heart rate monitor-based predictions of oxygen uptake and energy expenditure.

To validate VO2 and energy expenditure predictions by the Suunto heart rate (HR) system against a first principle gas analysis system, well-trained male (n = 10, age 29.8 +/- 4.3 years, VO2 65.9 +/- 9.7 ml x kg x min) and female (n = 7, 25.6 +/- 3.6 years, 57.0 +/- 4.2 ml x kg x min) runners completed a 2-stage incremental running test to establish submaximal and maximal oxygen uptake values. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sport nutrition and exercise metabolism

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2012