Detection of Airborne Bacteria and Mildew in the Shanghai Metro System
نویسندگان
چکیده
This study aimed to detect and to identify the main strains of airborne microorganisms present in the Shanghai Metro system. Samples were collected using agar plates exposed to the air and microorganisms were identified using catalase, plasma coagulase and hymolytic analysis. The results show that the concentration of mildew present within a newly opened metro line was significantly higher than for other lines. Differences among underground and elevated stations can be attributed to differences in passenger flow and the environment surrounding the stations. Additionally, the investigation indicated that bacteria reached maximum levels at different times on weekdays and weekends. The bacteria in the Metro stations were identified as primarily Gram positive, consisting mainly of coagulase-negative staphylococcus strains (CNS). Keywords—Bacteria, environment, Metro system, mildew, passenger flow.
منابع مشابه
Characteristics of Antibiotic Resistance of Airborne Staphylococcus Isolated from Metro Stations
This study focused on the presence of antibiotic-resistant bacteria in a metro system as an example of a public transportation system. The molecular characteristics of Staphylococcus were investigated to discern which strains were isolated from metro stations in Shanghai. These were compared with strains isolated from hospital treatment rooms and parks. Airborne Staphylococcus samples in the me...
متن کاملDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...
متن کاملSimulation of Metro Train Fire in an Underground Station of Tehran Metro Line 7
In this research a fire scenario was simulated in one of the stations of the line 7 of Tehran's subway system. The Line 7 is under construction and the ventilation system is under design. Fire was set for a stopping metro train at the platform of the station. A 160 meter length eight-car metro train with the forth wagon on the fire was studied. The heat release rate is based on a quadratic f...
متن کاملAssociation analysis for traits associated with powdery mildew tolerance in barley [Hordeum vulgare L.] using AFLP markers
Association analysis is a useful method for evaluation of significant association between molecular marker and phenotype of trait. This study was performed to evaluate association between traits related with powdery mildew resistance and molecular markers. This investigation was performed using 77 barley genotypes and AFLP markers. In phenotypic evaluation, reaction of seedlings to powdery mild...
متن کاملConstrained Controller Design for Real-time Delay Recovery in Metro Systems
This study is concerned with the real-time delay recovery problem in metro loop lines. Metro is the backbone of public transportation system in large cities. A discrete event model for traffic system of metro loop lines is derived and presented. Two effective automatic controllers, linear quadratic regulator (LQR) and model predictive controller (MPC), are used to recover train delays. A newly-...
متن کامل