Dosimetric Analysis of Prone Breast Treatment in Tomotherapy and Conventional Linear Accelerator
نویسندگان
چکیده
Purpose: To evaluate planning quality and dosimetric differences of clinically deliverable 3D conformal plans generated from Tomotherapy with TomoDirectTM (TD) and conventional field-in-field approach in prone breast treatment. Materials and methods: Total of twelve randomly selected early stage left breast patients who went through lumpectomy and were previously treated on traditional Linear Accelerator (LINAC) have been re-planned and tested on Tomotherapy TomoDirect module. Baseline prescription dose was chosen at 50.4 Gy (1.8 Gy × 28 fractions) to cover ≥95% of PTV for planning criteria with other critical structure dose constraints in the thoracic region. Planning outcomes such as D95 (95% of volume of PTV receiving the prescribed dose), D5 and D1, heart, both lungs as well as the contralateral breast were simultaneously evaluated. Conformity of the prescription isodose/volume to PTV was evaluated as conformity index (CI) and dose uniformity was also evaluated with homogeneity index (HI) in the same study series. All outcome parameters were analyzed and summarized to evaluate dosimetric impact of planning qualities between these two planning platforms. Results: The planning results indicate that CI, HI, D95, D5 and D1 of PTV, critical structures such as heart, ipsilateral and contralateral lungs as well as contralateral breast doses were comparable but with better overall statistical end points from TD plans. The D95, D5 and D1 of PTV for TD plans were superior in dosimetric analysis and more uniform than those plans generated from PinnacleTM field-in-field planning technique. Overall, TD plans have superior planning quality than the conventional method does, with straightforward and automated planning process once the beam delivery parameters were established. Conclusions: From the clinical treatment planning results, plans from TD in general achieved better uniform tumor coverage with fewer hot spots while sparing more critical structures were based upon isodose distribution and Dose Volume Histogram (DVH) analysis. Image guidance of TD delivery automates the setup within the treatment bore without tedious verification process compared to the process with LINAC. Though all plans are deliverable, TD planning possesses dosimetric advantages due to its modulated optimization pattern. However, TD did present a challenge during the simulation if a patient is oversized with long pendulant breast which is hard to fit into the Tomotherapy ring structure. From our analysis, TD plans reserve superior dosimetric outcome with CI, HI, D95, D5, and D1 of PTV, and better sparing contralateral lung and breast doses.
منابع مشابه
Breast Conserving Treatment for Breast Cancer: Dosimetric Comparison of Sequential versus Simultaneous Integrated Photon Boost
BACKGROUND Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining norm...
متن کاملTomotherapy – a different way of dose delivery in radiotherapy
AIM OF THE STUDY Helical tomotherapy is one of the methods of radiotherapy. This method enables treatment implementation for a wide spectrum of clinical cases. The vast array of therapeutic uses of helical tomotherapy results directly from the method of dose delivery, which is significantly different from the classic method developed for conventional linear accelerators. The paper discusses the...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملQuality assurance of a helical tomotherapy machine.
Helical tomotherapy has been developed at the University of Wisconsin, and 'Hi-Art II' clinical machines are now commercially manufactured. At the core of each machine lies a ring-gantry-mounted short linear accelerator which generates x-rays that are collimated into a fan beam of intensity-modulated radiation by a binary multileaf, the modulation being variable with gantry angle. Patients are ...
متن کاملA feasibility study using TomoDirect for craniospinal irradiation
The feasibility of delivering craniospinal irradiation (CSI) with TomoDirect is investigated. A method is proposed to generate TomoDirect plans using standard three-dimensional (3D) beam arrangements on Tomotherapy with junctioning of these fields to minimize hot or cold spots at the cranial/spinal junction. These plans are evaluated and compared to a helical Tomotherapy and a three-dimensional...
متن کامل