Exploiting coherence for real-time studies by single-bunch imaging

نویسندگان

  • A. Rack
  • M. Scheel
  • L. Hardy
  • C. Curfs
  • A. Bonnin
  • H. Reichert
چکیده

First real-time studies of ultra-fast processes by single-bunch imaging at the European Synchrotron Radiation Facility are reported. By operating the storage ring of the ESRF in single-bunch mode with its correspondingly increased electron bunch charge density per singlet, the polychromatic photon flux density at insertion-device beamlines is sufficient to capture hard X-ray images exploiting the light from a single bunch (the corresponding bunch length is 140 ps FWHM). Hard X-ray imaging with absorption contrast as well as phase contrast in combination with large propagation distances is demonstrated using spatial samplings of 11 µm and 35 µm pixel size. The images acquired allow one to track crack propagation in a bursting piece of glass, breaking of an electrical fuse as well as cell wall rupture in an aqueous foam. Future developments and their potential in the frame of the proposed Phase II of the ESRF Upgrade Program are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-shot electron-beam bunch length measurements.

We report subpicosecond electro-optic measurements of the length of individual relativistic electron bunches. The longitudinal electron-bunch shape is encoded electro-optically on to the spectrum of a chirped laser pulse. The electron-bunch length is determined by analyzing individual laser-pulse spectra obtained with and without the presence of an electron bunch. Since the length of the chirpe...

متن کامل

A Non-interrupting Electron Beam Diagnostic Using Coherent Off-axis Undulator Radiation

We propose a technique for measuring the length of an electron bunch from a linear accelerator without interrupting the electron beam. Bunch lengths are measured by observing off-axis undulator radiation. The wavelength of undulator radiation increases with the angle of emission. At angles as large as 10 degrees, the wavelength may be longer than the electron bunch, and as a result coherence ef...

متن کامل

Coherent Diffraction Radiation Imaging Methods to Measure RMS Bunch

The measurement of beam bunch length with high resolution is very important for the latest generation light sources and also a key parameter for the optimization of the final beam quality in high gradient plasma accelerators. In this contribution we present progress in the development of novel single shot, RMS bunch length diagnostic techniques based on imaging the near and far fields of cohere...

متن کامل

Sub-picosecond electron bunch length measurement by terahertz radiation S.Zhang S.Benson D.Douglas M.Shinn and G.Williams

This paper presents the measurement of sub-picosecond relativistic electron beam bunch length by analyzing the spectra of the coherent terahertz pulses through Kramers-Kronig transformation. The results are compared with autocorrelation from a scanning polarization autocorrelator that measures the coherent optical transition radiation. The limitations of the different methods to such a characte...

متن کامل

Temporal evolution of longitudinal bunch profile in a laser wakefield accelerator

We present single-shot measurements of the longitudinal bunch profile from a laser-wakefield accelerator with sub-fs resolution, based on detection of coherent transition radiation in a broad spectral range. A previously developed phase retrieval algorithm enables reconstruction of the bunch profile without prior assumptions about its shape. In this study, a variable-length gas target is used t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2014