Pilot study comparing the efficacy of two cleaning techniques in reducing environmental contamination with cyclophosphamide.

نویسندگان

  • Karine Touzin
  • Jean-François Bussières
  • Eric Langlois
  • Michel Lefebvre
  • Angélique Métra
چکیده

OBJECTIVE Compare the efficacy of the cleaning technique usually employed in our healthcare facility to eliminate environmental contamination with cyclophosphamide with that of the Surface Safe commercial kit. METHODS This is a three-step evaluative and comparative study involving: (i) the voluntary contamination of the surface of a hood with a pre-established quantity of cyclophosphamide (20,000,000 ng), (ii) the cleaning of the work surface of the hood using a cleaning technique usually employed in our healthcare facility or that of the product Surface Safe, and (iii) the quantification of cyclophosphamide detected on the work surface. The usual cleaning technique involves the use of a mixture of 0.05% chlorhexidine and 70% ethyl alcohol to clean surfaces, whereas the product Surface Safe involves a combined two-step sodium hypochlorite and sodium thiosulfate wash. RESULTS The median concentrations of cyclophosphamide detected after the use of the usual technique and the product Surface Safe came to 165 ng cm(-2) (40-570) and 65 ng cm(-2) (57-110), respectively. The results obtained showed an average 99.5% efficacy in reducing the quantity of cyclophosphamide (ng) detected on the work surface for each of the two techniques that were evaluated. CONCLUSION The study demonstrates that reducing the residual concentration of cyclophosphamide on work surfaces to levels lower than 1 ng cm(-2) remains difficult despite the use of cleaning techniques with a high percentage of efficacy. It stressed the importance of combining two successive cleaning techniques to maximally restrict the residual concentration of hazardous drugs and suggests the use of a combination of sodium hypochlorite and sodium thiosulfate to best reduce environmental contamination levels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclophosphamide contamination observed on the external surfaces of drug vials and the efficacy of cleaning on vial contamination.

OBJECTIVE Evaluate contamination on the external surfaces of cyclophosphamide vials available on the Canadian market during storage in pharmacy departments and the efficacy of decontaminating the external surfaces of vials using various cleaning techniques. METHODS The study consisted of three phases: the quantification of cyclophosphamide on the external surfaces of 10 vials of Procytox and ...

متن کامل

A case study: surface contamination of cyclophosphamide due to working practices and cleaning procedures in two Italian hospitals.

The efficacy of preventive and organisational measures implemented in Italy to prevent the contamination of cytotoxic drug preparation rooms has been investigated, and oncologic wards of two Italian hospitals were examined. The sampling strategy was based not only on potential sources of contamination but also on responses to detailed questionnaires on workplace practices and work organisation....

متن کامل

Evaluating the Cleaning Program Efficacy in ICU Ward of General Hospital Using Visual and Microbial Approaches

Background & Aims of the Study: Hospital infectious is one of the major causes of mortality among the hospitalized cases. The interior environment status of hospitals has the important rule in microbial transmission.  Translocation of the infectious agents may be essentially due to contacts between patients and contaminated interior environment. This work was performed to ...

متن کامل

بررسی آلودگی سطوح با داروهای سیکلوفسفامید و ایفسفامید در مراکز کموتراپی

  Background and purpose: Cyclophosphamide and ifosfamide are two most widely used and hazardous drugs in chemotherapy centers. This study aimed at determining surface contamination with cyclophosphamide and iphosphamide in chemotherapy centers. Materials and methods: This descriptive cross-sectional study was carried out in three chemotherapy centers affiliated with Hamedan University o...

متن کامل

ارزیابی خطر انتقال عفونت های بیمارستانی در بخش مراقبت های ویژه بیمارستان بهشتی کاشان درسال 1390

Background: Microbial contaminations occurred in “Intensive Care Unit” (ICU) is the substantial cause of infection transmission within hospitals. The infectious organisms can be transmitted mainly through contact with the surface of instruments. Indicating the contaminated sources is the primary step during the infection control program. This study aimed to evaluate the risk of cross infection ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2010