Toward high sequence coverage of proteins in human breast cancer cells using on-line monolith-based HPLC-ESI-TOF MS compared to CE MS.
نویسندگان
چکیده
A method is developed toward high sequence coverage of proteins isolated from human breast cancer MCF10 cell lines using a 2-D liquid separations. Monolithic-capillary columns prepared by copolymerizing styrene with divinylbenzene are used to achieve high-resolution separation of peptides from protein digests. This separation is performed with minimal sample preparation directly from the 2-D liquid fractionation of the cell lysate. The monolithic column separation is directly interfaced to ESI-TOF MS to obtain a peptide map. The protein digests were also analyzed by MALDI-TOF MS and an accurate M(r) of the intact protein was obtained using an HPLC-ESI-TOF MS. The result is that these techniques provide complementary information where nearly complete sequence coverage of the protein is obtained and can be compared to the experimental M(r) value. The high sequence coverage provides information on isoforms and other post-translational modifications that would not be available from methods that result in low sequence coverage. The results from the use of monolithic columns are compared to that obtained by CE-MS. The monolithic column separations provide a rugged and highly reproducible method for separating protein digests prior to MS analysis and is suited to confidently identify biomarkers associated with cancer progression.
منابع مشابه
Proteomic profiling identifies breast tumor metastasis-associated factors in an isogenic model.
A combination of LC and MS was applied to an isogenic breast tumor metastasis model to identify proteins associated with a cellular phenotype. Chromatofocusing followed by nonporous-RP-HPLC/ESI-TOF MS was applied to cell lysates of a pair of monoclonal cell lines from the human breast carcinoma cell line MDA-MB-435 that have different metastatic phenotypes in immune-compromised mice. This metho...
متن کاملA comparison of liquid chromatography, capillary electrophoresis, and mass spectrometry methods to determine xyloglucan structures in black currants.
Different separation (HPAEC, RP-HPLC, CE) and identification (MALDI-TOF-MS, ESI-MS(n)) techniques were compared to analyse oligosaccharides obtained after incubation of xyloglucan with endo-glucanase. It was possible to analyse xyloglucan oligosaccharides with each technique. Several techniques, including off line (HPAEC-MALDI-TOF-MS) or online (CE-ESI-MS(n), RP-HPLC-ESI-MS(n)) connection provi...
متن کاملIdentification of proteins from two-dimensional gel electrophoresis of human erythroleukemia cells using capillary high performance liquid chromatography/electrospray-ion trap-reflectron time-of-flight mass spectrometry with two-dimensional topographic map analysis of in-gel tryptic digest products.
Protein spots from two-dimensional (2-D) gel electrophoresis of a human erythroleukemia cell line have been identified by analysis of the in-gel tryptic digests using capillary high performance liquid chromatography (HPLC) separation with on-line detection using electrospray ionization mass spectrometry (ESI-MS). This is performed using an electrospray/ion trap storage/reflectron time-of-flight...
متن کاملDifferential expression of acidic proteins with progression in the MCF10 model of human breast disease.
A proteomic characterization of one premalignant (MCF10AT1) and two malignant (MCF10CA1a and MCF10 CA1d) human breast cancer cell lines has been performed using a combination of two-dimensional liquid separations and mass spectrometry. Chromatofocusing (CF) and NPS-RP-HPLC are combined with ESI-TOF-MS to resolve and detect intact proteins. Simultaneously, fractions are collected and digested fo...
متن کاملProteomic analysis of estrogen response of premalignant human breast cells using a 2-D liquid separation/mass mapping technique.
A 2-D liquid-phase separation method based on chromatofocusing and nonporous silica RP-HPLC followed by ESI-TOF-MS was used to analyze proteins in whole cell lysates from estrogen-treated and untreated premalignant, estrogen-responsive cell line MCF10AT1 cells. 2-D mass maps in the pH range 4.6-6.0 were generated with good correlation to theoretical M(r) values for intact proteins. Proteins wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 27 11 شماره
صفحات -
تاریخ انتشار 2006