A more accurate method acquirement by a comparison of the prediction equations for estimating glomerular filtration rate in Chinese patients with obstructive nephropathy

نویسندگان

  • Meixue Chen
  • Jumei Xia
  • Guangchang Pei
  • Ying Zhang
  • Shuting Wu
  • Yushuang Qin
  • Yuanjun Deng
  • Shuiming Guo
  • Yanyan Guo
  • Gang Xu
  • Min Han
چکیده

BACKGROUND Researchers have developed several equations to predict glomerular filtration rate (GFR) in patients with chronic kidney diseases (CKD). However, there are scarcely any studies performed to discern the best equation to estimate GFR in patients with pure obstructive nephropathy. In present study, we assessed the suitability of six prediction equations and compared their performance in eGFR evaluation for Chinese patients with obstructive nephropathy. METHODS A total of 245 adult patients with obstructive nephropathy were enrolled. We evaluated the performance of the 3 Modification of Diet in Renal Disease equations (MDRD) (the original MDRD7, 7MDRD; the abbreviated MDRD, aMDRD; and re-expressed abbreviated MDRD, re-aMDRD) and 3 Chronic Kidney Disease Epidemiology Collaboration equations (CKD-EPI) (CKD-EPI equation based on creatinine alone, CKD-EPIcr; CKD-EPI equation based on cystatin C alone, CKD-EPIcys; CKD-EPI equation based on combined creatinine-cystatin, CKD-EPIcr-cys). The measured GFR (mGFR) by 99mTc-DTPA renal dynamic imaging method was used as the reference GFR. RESULTS The mean age of the study population was 51.61 ± 14.17 and 131 were male (53.47 %). The mean measured GFR was 66.54 ± 23.99 ml/min/1.73 m2. Overall, the CKD-EPIcr-cys equation gave the best performance with the best correlation (R = 0.72) and agreement (-34.87, 40.83). CKD-EPIcr-cys equation also exhibited the highest accuracy (69.39 %, P < 0.01) and diagnostic efficacy (ROCAUC = 0.874) with the smallest bias (2.98, P < 0.01). In the subgroup of the lowest GFR, CKD-EPIcys equation exhibited the highest accuracy (52.69 %) and the smallest bias (0.27). In the youngest age subgroup, CKD-EPIcys equation had the highest accuracy (71.64 %) and the smallest bias (-1.24). In other subgroups stratified by GFR, age and gender, CKD-EPIcr-cys equation remained the best performance. CONCLUSION The 3 CKD-EPI equations performed better than the 3 MDRD equations in estimating GFR in Chinese obstructive nephropathy patients; while the CKD-EPI equation based on combined creatinine-cystatin C provided the best estimation of GFR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease

Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

The Chronic Kidney Disease Epidemiology Collaboration equation improves the detection of hyperfiltration in Chinese diabetic patients.

OBJECTIVE Hyperfiltration confers an increased risk of diabetic nephropathy. Early detection can ensure timely intervention and improved treatment outcomes. Because GFR is known to be affected by hyperglycemia, the aim of this study was to compare the influence of hyperglycemia on GFR estimations calculated by the CKD-EPI equation, the CG equation, and the MDRD equations in estimating hyperfilt...

متن کامل

بررسی ارتباط میزان فیلتراسیون گلومرولی (GFR) با عملکرد کبد در بیماران سیروز کبدی

Background and purpose: Serum creatinine and its derived formulae in estimating glomerular filtration rate is not accurate in cirrhotic patients because of decreased muscle mass and secretion and excretion functional impairment of liver. This study aimed at investigating the accuracy of serum cystatin C in determining GFR and examining the relationship between synthetic and excretory liver func...

متن کامل

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016